Faithtech FT68200 Operation Manual
14
1.4.6. Performance Specification (24kW)
Model
FT68224A/E-150-2400
FT68224A/E-600-1680
FT68224A/E-1200-960
voltage
150V
600V
1200V
Current
2400A
1680A
960A
Power
24000W
24000W
24000W
U
min
@I
max
1.5V@2400A
14V@1680A
20V@960A
Constant Current
Range
240A
2400A
168A
1680A
96A
960A
Resolution 4mA
40mA
2.8mA
28mA
1.6mA
16mA
Accuracy
0.05%+0.05%F.S.
0.05%+0.05%F.S.
0.05%+0.05%F.S.
Constant Voltage
Range
30V
150V
120V
600V
240V
1200V
Resolution 0.5mV
2.5mV
2mV
10mV
4mV
20mV
Accuracy
0.025%+0.025%F.S.
0.025%+0.025%F.S.
0.025%+0.025%F.S.
Constant Resistance
Range
0.002
~
13
Ω
0.02
~
63
Ω
0.013
~
71
Ω
0.13
~
357
Ω
0.046
~
250
Ω
0.46
~
1250
Ω
Accuracy
Vin/Rset*(0.2%)+0.2%IF.S. Vin/Rset*(0.2%)+0.2%IF.S
Vin/Rset*(0.2%)+0.2%IF.S
Constant Power
Range
24000W
24000W
24000W
Accuracy
0.2%+0.2% F.S.
0.2%+0.2% F.S.
0.2%+0.2% F.S.
Dynamic
T1&T2
10us
~
60S
10us
~
60S
10us
~
60S
Resolution 2us
2us
2us
Accuracy
1us+20PPM
1us+20PPM
1us+20PPM
Slew Rate
0.001
~
2.4A/us
0.01
~
24A/us
0.001
~
1.6A/us
0.01
~
16A/us
0.001
~
0.96A/us
0.01
~
9.6A/us
Current Measurement
Range
240A
2400A
168A
1680A
96A
960A
Resolution 4mA
40mA
2.8mA
28mA
1.6mA
16mA
Accuracy
0.05%+0.05%F.S.
0.05%+0.05%F.S.
0.05%+0.05%F.S.
Voltage Measurement
Range
30V
150V
120V
600V
240V
1200V
Resolution 0.5mV
2.5mV
2mV
10mV
4mV
20mV
Accuracy
0.025%+0.025%F.S.
0.025%+0.025%F.S.
0.025%+0.025%F.S.
AC INPUT 220VAC±10%, (50
~
60)Hz , 1420VA
Temp
(0
~
40)
℃
Weight
156kg
Dimension 482.6mm(W) * 621.0mm(H) * 712.2mm(L)
Summary of Contents for FT68200 Series
Page 9: ...Faithtech FT68200 Operation Manual 3 1 3 2 7U 8kW 10kW 12kW...
Page 10: ...Faithtech FT68200 Operation Manual 4 1 3 3 11U 14kW 16kW 18kW...
Page 11: ...Faithtech FT68200 Operation Manual 5 1 3 4 14U 20kW 22kW 24kW...
Page 12: ...Faithtech FT68200 Operation Manual 6 1 3 5 20U 30kW 36kW...
Page 13: ...Faithtech FT68200 Operation Manual 7 1 3 6 26U 42kW 48kW...
Page 14: ...Faithtech FT68200 Operation Manual 8 1 3 7 32U 54kW 60kW...