3-13 Slew rate and conversion time relation
Notice:
When the load is switching from a small current value to a large current
value, the minimum conversion time is equal to the current difference divided by the
current slew rate, but when the load is switching from a large current to a small current
value, due to the small signal bandwidth limitation of the load, the minimum conversion
time will be longer than the time calculated by the formula.
3.5. Input Control
After the load is powered on, it is in an unloaded state, and the input switch of the
load can be controlled by the
keys on the front panel.
key is lighted on, indicating that the input is turned on, and the real-time
voltage and current information is displayed on the screen;;
key is lighted off, indicating that the input is closed.
The screen displays the status of the input switch, and the user can also observe
whether the input is on or off through the
key light.
3.6. Short circuit simulation
Under the static test function and dynamic test function, the electronic load can simulate
short-circuit operation to test the protection performance of the DUT. The current consumed