Pellets Stove
22
22
22
22
technician
•
Replace the card, cod Com0231.
Call a specialised technician
•
Call an expert stove setter to verify if
the chimney is according to the law
(see paragraph 2)
•
When there is a very strong wind a
negative depression to the chimney
can occur. Verify and start the stove
again
•
The stove switches
OFF. Alarm displayed
“AlAr Sic”
•
Stove overheated
•
The exchanger fan doesn’t work
•
Temporary power failure
•
Faulty thermostat
•
Air filter obstructed
•
Faulty electronic card
•
Let the stove cool down and stoke it
again, if the problem continues call a
specialised technician
•
Replace the fan, cod Com0237. Call
a specialised technician
•
A voltage failure during the
functioning of the stove causes an
overheating of the boiler and it is
necessary to stoke it again and start
the stove.
•
Replace the thermostat, cod
Com0238. Call a specialised
technician
•
Clean the filter (see Maintenance)
•
Replace the card, cod Com0231.
Call a specialised technician
•
The stove switches off.
Alarm displayed “AlAr
hottemp”
•
Fumes feeler is faulty
•
Electronic card faulty
•
The environment exchanger fan
doesn’t work
•
Too high parameter set on card during
phase 5
•
Replace the feeler, cod Com0239.
Call a specialised technician
•
Replace the card, cod Com0231.
Call a specialised technician
•
Replace the fan, cod Com0237. Call
a specialised technician
•
Call a specialised technician to
regulate the pellets stoke
•
The stove switches off.
Alarm displayed “AlAr
Sond”
•
Fumes temperature feeler
disconnected
•
Fumes temperature feeler is faulty
•
Verify the feeler is connected to the
card and/or put in and blocked in the
seat of the extractor. Call a
specialised technician
•
Replace the feeler, cod Com0239.
Call a specialised technician