stoke pellets and the resistance will keep warming up. When the temperature is high enough, thanks to the 
fume gas feeler, the electronic gear case (after 7-10 minutes) will consider the starting phase ended and start 
the next phase of flame stabilisation displaying “FirE on” and starting the tangential ventilator (heat 
exchanger). When the “FirE on” phase ends, the gear case will set the work state, displaying the chosen 
heating power (you can change it with keys P6 and P5) and the environment temperature. During this phase 
keys P5 and P6 can regulate the stove power from 1 to 5. If the environment temperature exceed the limit 
parameter fixed on key-board during the temperature setting the heating power will decrease to minimum 
rate until the parameter is back to its prefixed limit and the display will show “RiS”. 
 

Non

Non

Non

Non----starting

starting

starting

starting    

 
If pellets don’t light up, the non-starting will be indicated by an alarm “AlAr no FirE”. The stove starting takes 
about 7/10 minutes with good quality pellets and an environment temperature of about 10°C. If the 
environment temperature is lower, the starting plug is not able to start the stove; in this case you can help 
putting a lighted igniter on the brazier.  
 

Energy failure

Energy failure

Energy failure

Energy failure    

 
After an energy blackout, when the stove is restored it will display “AlAr no rEtE”. The fumes gas extractor 
will discharge the fumes residuals for 20 minutes starting the switching off phase. When the cooling phase is 
completed, empty the brazier from excessive pellets and start the stove again. 
 
To bypass the start stage (e.g. the fire goes out unintentionally): just press key (6) for about 2 sec. and the 
stove will immediately go into the ON operating phase; it is only possible to jump the startup phase if the 
smoke temperature (detected by the probe) is over 55°-60°C. Below these values, after several seconds the 
stove will return to the “Fan Cand” startup stage. 
 

Temperature setting

Temperature setting

Temperature setting

Temperature setting    

 
To modify the environment temperature you can press any time key P3 together with P1 or P2 to regulate it. 
The chosen temperature and the environment temperature will be displayed on display b. 
 

Fumes gas temperature

Fumes gas temperature

Fumes gas temperature

Fumes gas temperature    

 
To verify the fumes gas temperature at the outlet keep key P1 pressed for few seconds. 
 

Switching off

Switching off

Switching off

Switching off    

 
To switch off the stove keep P4 pressed,  “OFF” will be displayed on display a. During this phase the stoking 
of pellets is stopped, the tangential fan is switched off and after 20 minutes the fumes extractor is turned off 
too (that occurs anyway if the stove is hot or cold). 
 

To put off the fire

To put off the fire

To put off the fire

To put off the fire    

 
If it happens you suddenly have to put off the fire burst out from the stove or chimney flue, use carbon dioxide 
extinguisher (CO2) or ask for the fire-brigade intervention. Do not use water to put off the fire in the brazier. 
 

Pellets stoking

Pellets stoking

Pellets stoking

Pellets stoking    

 
If you have to stoke the stove with pellets while it is working, make sure the pellets bag doesn’t get in contact 
with any hot surface. Make sure the pellets tank is always closed with its lid. Don’t put any residuals of 
combustible material (unburned embers) of the brazier into the pellets tank. 
 

Clock setting

Clock setting

Clock setting

Clock setting    

 
To set the clock press key P3 some times until the green led with the clock lights up and “UT02” is displayed, 
then you can regulate time with keys P1 and P2. 
 
 
 

Summary of Contents for S7

Page 1: ...Maintenance And Use Manual Pellets Stove Pellets Stove Pellets Stove Pellets Stove...

Page 2: ...roduct Fair will not be liable in the event of failure to respect these instructions This stove should be used for the purposes for which it was designed and made The manufacturer is excluded from any...

Page 3: ...s solid combustible materials of b type with forced draft as modern heating appliances are high efficient with colder fumes and a consequent lower draft it is really important that the chimney flue is...

Page 4: ...atio between the inner sides must be 1 5 and the linked sides must have a minimum radius of 20 mm The section dimensions must be equal to or bigger than the diameter of the fumes waste pipe 8cm Hereun...

Page 5: ...External air intake External air intake External air intake External air intake We recommend to set an air intake from the outside to have a healthy inner environment The air flow between the outside...

Page 6: ...e of problem we recommend installing a permanent ventilation grid in a window or near the stove Air intake directly from the outside is compulsory WARNING Use only steel pipes Pipes in synthetic mater...

Page 7: ...made of stainless steel A316 or porcelain zed minimum thickness 0 5mm with a diameter of 80 mm or 100mm depending on the type of plant see picture 2 pag 4 you can not use pipes made of asbestos cemen...

Page 8: ...ot use inflammable liquids Pellets are the only combustible material you can use You can find different kind of pellets with different characteristics and quality on sale We recommend to use pellets o...

Page 9: ...t be installed in isolation with a minimum air space of 15 cm to allow an adequate cooling of the appliance and a good distribution of heat in the domestic environment In compliance with fire preventi...

Page 10: ...by the moto ventilators keeps the stove temperature low preventing the materials the stove is made of from excessive stress and heating the domestic environment more homogeneously Make sure you period...

Page 11: ...rol panel Control panel Control panel Control panel Key P1 and P2 when you are setting the temperature they increase or decrease the thermostat parameter from minimum 06 C to maximum 41 C If you keep...

Page 12: ...stove will immediately go into the ON operating phase it is only possible to jump the startup phase if the smoke temperature detected by the probe is over 55 60 C Below these values after several sec...

Page 13: ...y when you want to start program 1 2 3 or 4 Pressing P1 and P2 you can choose the wanted parameter UT05 UT06 indicates starting and ending time of the functioning of the stove in program 1 They are ac...

Page 14: ...er is damaged or disconnected AlAr Sond will appear on display The electronic card stops the electric input to the cochlea blocking the pellets stoking to the brazier and starting the switching off ph...

Page 15: ...and the stove cool down and disconnect it from electrical power supply Filter cleaning Filter cleaning Filter cleaning Filter cleaning The stove is equipped with a filter against dust which is placed...

Page 16: ...he obstructed holes Clean also the brazier room from ash left inside The frequency of the cleaning depe depe depe depends on the type of pellets Pay attention to the flame colour if it is red that mea...

Page 17: ...5 5 12 5 5 12 5 5 11 5 5 11 Average temperature fumes 78 206 C 78 206 C 78 206 C 78 206 C 78 167 C 78 167 C Mass flow fumes 3 3 5 6 g s 3 3 5 6 g s 3 3 5 6 g s 3 3 5 6 g s 3 3 5 0 g s 3 3 5 0 g s Tan...

Page 18: ...Pellets Stove 18 18 18 18 Wiring diagram Wiring diagram Wiring diagram Wiring diagram...

Page 19: ...Pellets Stove 19 19 19 19...

Page 20: ...Pellets don t get to the fire box The tank is empty Cochlea is blocked by a strange object ex Nails Cochlea gear motor is damaged Verify if there is an alarm activated on display ex AlAr dEP AlAr Sic...

Page 21: ...ce the card cod Com0231 Call a specialised technician The stove is in steady condition the display shows RiS Environment temperature reached Fumes outlet temperature reached The stove works at minimum...

Page 22: ...necessary to stoke it again and start the stove Replace the thermostat cod Com0238 Call a specialised technician Clean the filter see Maintenance Replace the card cod Com0231 Call a specialised techni...

Page 23: ...e or of Fair srl discover while doing repairs that the date of installation first startup is not the true one which can be detected from identifying details and other elements in the equipment The pre...

Page 24: ...number Serial number Serial number Tests carried out Tests carried out Tests carried out Tests carried out Automatic ignition Automatic ignition Automatic ignition Automatic ignition Combustion air mo...

Page 25: ...ised T Specialised Technical Servicing Centre echnical Servicing Centre echnical Servicing Centre echnical Servicing Centre Work done on Work done on Work done on Work done on Material used Guarantee...

Page 26: ...ntre Specialised Technical Servicing Centre Specialised Technical Servicing Centre Specialised Technical Servicing Centre Work done on Work done on Work done on Work done on Material used Guarantee YE...

Page 27: ...Pellets Stove 27 27 27 27...

Page 28: ...FAIR s r l Via Lago di Costanza 24 36015 Schio VI ITALIA Tel 0445 698000 Fax 0445 698100 e mail info fair europe com http www fair europe com Fair 2009 rev 1 10 10 09...

Reviews: