stove fitter to check the chimney
from the stove outlet to the chimney
pot). Have it cleaned immediately.
•
Clean the stove inside (see
Maintenance)
•
Pellets can burn thanks to the
chimney flue depression without the
aspirator. Have it replaced
immediately (cod. Com0236) as it
can be bad for your health. Call a
specialised technician.
•
The exchanger fan
keeps working when
the stove is cold
•
Temperature fumes feeler is faulty
•
Electronic card is faulty
•
Replace the fumes feeler, cod
Com0239. Call a specialised
technician
•
Replace the card, cod Com0231.
Call a specialised technician
•
Hash around the stove
•
Faulty or damaged doors strips
•
Fumes pipe tubes are not airtight
•
Replace the strips cod.
Com0245
•
Seal immediately the pipe fitting
(with high temperature silicone)
and/or replace the pipes with new
ones. Fumes pipes that aren’t
airtight can be dangerous for your
health. Call an expert stove fitter.
•
The stove switches off.
Alarm displayed “AlAr
no rEtE”
•
Plug accidentally unplugged
•
Temporary power failure
•
Faulty electronic card
•
Verify the plug is plugged in
•
Verify the power failure and start the
stove again
•
Replace the card, cod Com0231.
Call a specialised technician
•
The stove is in steady
condition, the display
shows: “RiS”
•
Environment temperature reached
•
Fumes outlet temperature reached
•
The stove works at minimum rate: no
problem
•
The stove works at minimum rate: no
problem
•
When working normally
the stove display
shows “Stop Fire”
•
Cleaning grate
•
The stove goes to minimum and
extraction ventilation to maximum:
no problem
•
The stove switches off.
Alarm displayed: “AlAr
dEP”
•
The door isn’t closed
•
The waste outlet is obstructed
•
Fumes extractor is damaged
•
Rubber connection is obstructed
•
Pressure switch is faulty
•
Electronic card is faulty
•
Excessive chimney length
•
Bad weather conditions
•
Closed the door properly and check
the door strips are in good
conditions otherwise replace them
cod. Com0245
•
The fumes waste chimney is partially
or totally obstructed (call an expert
stove fitter to check the chimney
from the stove outlet to the chimney
pot). Have it cleaned immediately.
•
Pellets can burn thanks to the
chimney flue depression without the
aspirator. Have it replaced
immediately (cod. Com0236) as it
can be bad for your health. Call a
specialised technician.
•
Take the silicone pipe off and with
the help of a pointed tool clean the
bodying hole. Replace the pipe if
necessary cod. Com0401
•
Replace the pressure switch, cod
Com0233. Call a specialised