background image

 

Pellets Stove

 

 
 

 

3

33

3    

 

PACKING

PACKING

PACKING

PACKING    

 

Packing

Packing

Packing

Packing    

 
The packing includes a cardboard box, which is recyclable in accordance with RESY guidelines, some 
recyclable inserts made of expanded EPS and wooden pallet. All package materials can be used again for 
similar use or taken away as solid urban waste in accordance with the regulation in force. 
After you have taken the package away make sure the appliance is in perfect conditions. 
Important: we recommend you move the appliance with adequate means paying attention to the safety 
regulation. Don’t turn the package upside down and handle the majolica details with care. 
 
 

 

CHIMNEY FLUE

CHIMNEY FLUE

CHIMNEY FLUE

CHIMNEY FLUE    

 

Introduction

Introduction

Introduction

Introduction    

 
This chapter gives you some directions for a good and correct fulfilment of the chimney flue but it doesn’t 
replace the regulations in force that a qualified chimney setter should know. 
The company declines any responsibility for the bad functioning of the stove if that is caused by a bad 
dimensioned chimney flue that is not in accordance with the regulation in force UNI10683. 
                     

Chimney flue

Chimney flue

Chimney flue

Chimney flue    

 
The chimney flue or chimney has a great importance for a heating appliance which uses solid combustible 
materials of b type with forced draft; as modern heating appliances are high efficient with colder fumes and a 
consequent lower draft it is really important that the chimney flue is properly built and always maintained 
perfectly efficient. The chimney flue must be single (regulation UNI7129/92) or going outside (regulation 
UNI7129/92) (see picture 1 a and b) which is not allowed in building with several floors and flats. It is not 
possible to connect more than one pellets appliance to the same chimney flue. 
 

 

 

 

 

Pic. 1 

 

Technical characteristics

Technical characteristics

Technical characteristics

Technical characteristics    

 
The chimney flue must be fume tight (a seepage of air through cracks or an inspection door which isn’t fume 
tight will highly reduce the draught of the chimney). It must be vertical without obstructions, made of materials 
that are impermeable to fumes and condensate, thermal insulated and adequate to be resistant against 
normal mechanical stress on a long term (we recommend chimneys made of a/316 or refractory material with 
double insulated chamber of round section). It must be insulated from the outside to avoid phenomenon of 
condensate and to decrease the effect of fumes cooling. It must be separated from materials that are 
combustible or easily inflammable by means of air space or insulating materials. The chimney fireplace throat 
must be located in the same room where the appliance is installed or at least in the next room and 

Summary of Contents for S7

Page 1: ...Maintenance And Use Manual Pellets Stove Pellets Stove Pellets Stove Pellets Stove...

Page 2: ...roduct Fair will not be liable in the event of failure to respect these instructions This stove should be used for the purposes for which it was designed and made The manufacturer is excluded from any...

Page 3: ...s solid combustible materials of b type with forced draft as modern heating appliances are high efficient with colder fumes and a consequent lower draft it is really important that the chimney flue is...

Page 4: ...atio between the inner sides must be 1 5 and the linked sides must have a minimum radius of 20 mm The section dimensions must be equal to or bigger than the diameter of the fumes waste pipe 8cm Hereun...

Page 5: ...External air intake External air intake External air intake External air intake We recommend to set an air intake from the outside to have a healthy inner environment The air flow between the outside...

Page 6: ...e of problem we recommend installing a permanent ventilation grid in a window or near the stove Air intake directly from the outside is compulsory WARNING Use only steel pipes Pipes in synthetic mater...

Page 7: ...made of stainless steel A316 or porcelain zed minimum thickness 0 5mm with a diameter of 80 mm or 100mm depending on the type of plant see picture 2 pag 4 you can not use pipes made of asbestos cemen...

Page 8: ...ot use inflammable liquids Pellets are the only combustible material you can use You can find different kind of pellets with different characteristics and quality on sale We recommend to use pellets o...

Page 9: ...t be installed in isolation with a minimum air space of 15 cm to allow an adequate cooling of the appliance and a good distribution of heat in the domestic environment In compliance with fire preventi...

Page 10: ...by the moto ventilators keeps the stove temperature low preventing the materials the stove is made of from excessive stress and heating the domestic environment more homogeneously Make sure you period...

Page 11: ...rol panel Control panel Control panel Control panel Key P1 and P2 when you are setting the temperature they increase or decrease the thermostat parameter from minimum 06 C to maximum 41 C If you keep...

Page 12: ...stove will immediately go into the ON operating phase it is only possible to jump the startup phase if the smoke temperature detected by the probe is over 55 60 C Below these values after several sec...

Page 13: ...y when you want to start program 1 2 3 or 4 Pressing P1 and P2 you can choose the wanted parameter UT05 UT06 indicates starting and ending time of the functioning of the stove in program 1 They are ac...

Page 14: ...er is damaged or disconnected AlAr Sond will appear on display The electronic card stops the electric input to the cochlea blocking the pellets stoking to the brazier and starting the switching off ph...

Page 15: ...and the stove cool down and disconnect it from electrical power supply Filter cleaning Filter cleaning Filter cleaning Filter cleaning The stove is equipped with a filter against dust which is placed...

Page 16: ...he obstructed holes Clean also the brazier room from ash left inside The frequency of the cleaning depe depe depe depends on the type of pellets Pay attention to the flame colour if it is red that mea...

Page 17: ...5 5 12 5 5 12 5 5 11 5 5 11 Average temperature fumes 78 206 C 78 206 C 78 206 C 78 206 C 78 167 C 78 167 C Mass flow fumes 3 3 5 6 g s 3 3 5 6 g s 3 3 5 6 g s 3 3 5 6 g s 3 3 5 0 g s 3 3 5 0 g s Tan...

Page 18: ...Pellets Stove 18 18 18 18 Wiring diagram Wiring diagram Wiring diagram Wiring diagram...

Page 19: ...Pellets Stove 19 19 19 19...

Page 20: ...Pellets don t get to the fire box The tank is empty Cochlea is blocked by a strange object ex Nails Cochlea gear motor is damaged Verify if there is an alarm activated on display ex AlAr dEP AlAr Sic...

Page 21: ...ce the card cod Com0231 Call a specialised technician The stove is in steady condition the display shows RiS Environment temperature reached Fumes outlet temperature reached The stove works at minimum...

Page 22: ...necessary to stoke it again and start the stove Replace the thermostat cod Com0238 Call a specialised technician Clean the filter see Maintenance Replace the card cod Com0231 Call a specialised techni...

Page 23: ...e or of Fair srl discover while doing repairs that the date of installation first startup is not the true one which can be detected from identifying details and other elements in the equipment The pre...

Page 24: ...number Serial number Serial number Tests carried out Tests carried out Tests carried out Tests carried out Automatic ignition Automatic ignition Automatic ignition Automatic ignition Combustion air mo...

Page 25: ...ised T Specialised Technical Servicing Centre echnical Servicing Centre echnical Servicing Centre echnical Servicing Centre Work done on Work done on Work done on Work done on Material used Guarantee...

Page 26: ...ntre Specialised Technical Servicing Centre Specialised Technical Servicing Centre Specialised Technical Servicing Centre Work done on Work done on Work done on Work done on Material used Guarantee YE...

Page 27: ...Pellets Stove 27 27 27 27...

Page 28: ...FAIR s r l Via Lago di Costanza 24 36015 Schio VI ITALIA Tel 0445 698000 Fax 0445 698100 e mail info fair europe com http www fair europe com Fair 2009 rev 1 10 10 09...