background image

®

Operating & Installation Instructions

AUSTRALIA

 

Summary of Contents for Bay BX

Page 1: ... Operating Installation Instructions AUSTRALIA ...

Page 2: ......

Page 3: ...RECAUTIONS 10 SPECIFICATION 10 FLUE 10 HEARTH AND FIRE SURROUND 10 CONNECTIONS TO FLUES 11 PRE LIGHTING CHECK 11 COMMISSIONING 11 STAND OPTIONS 11 TIS 129 FITTING THE CENTRE STAND 12 CLEARANCES 13 STANDARD HEARTH DIMENSIONS 14 CORNER HEARTH DIMENSIONS 15 FLUE CLEARANCES DIAGRAM 16 STANDARD DEFAULT TRIPLE SKIN FLUE KIT 17 INSULATED ROOM SEAL FLUE KIT 18 INSULATED ROOM SEAL FLUE KIT 19 COMPLIANCE DA...

Page 4: ...duced to medium output Baffle Improves efficiency of stove by slowing down flue gases Door Keep closed when stove is in use Door handle Pull to open Optional stand Three options available Centre Stand Store Stand Bench Stand Fuel retainer Ensure fuel does not protrude beyond retainer MAINTENANCE AND CLEANING GLASS Wipe with damp lint free cloth Any stubborn deposits on the glass may be removed wit...

Page 5: ...E WILL INVALIDATE THE GUARANTEE This stove is not designed to burn household waste LIGHTING On initial lighting the stove may smoke and give off an odour as the silicon paint with which the firebox is painted reacts to the heat This is normal and will cease after a short time but meanwhile the room should be kept well ventilated At first only light a small fire and burn it slowly for two hours to ...

Page 6: ...urning it is important to leave a layer of ash around 1cm thick on the base of the stove If the ash is becoming too deep clear the top layer of ash cleared using the scoop provided Fig 2 Ash Scoop REDUCED BURNING For reduced burning the fire door must be closed When burning wood in areas that are not smoke controlled load some large logs on the fire and allow to burn for half an hour before closin...

Page 7: ...n order to prevent potentially dangerous fume emission Check by looking up into the firebox for signs of soot or fly ash on the baffle plate and sides of the firebox If there are signs of a build up of soot or fly ash then cleaning is necessary Cleaning should occur at least once a month and more frequently if required Let the fire out and ensure it is cold before carrying out these operations If ...

Page 8: ... when running the stove very slowly for long periods If blackening of the glass still occurs check that all flue connections and the blanking plate are well sealed It is also important that the flue draw is sufficient and that it is not affected by down draught When the flue is warm a draught reading of at least 1 25 mm 0 05 in water gauge 12Pa should be obtained Some blackening of the glass may o...

Page 9: ...harnwood then your Installer will be able to provide the answers to most questions Your Local Charnwood Dealer has a great deal of experience and will also be able to provide helpful advice Further help is available from Pivot Stove Heating who will be pleased to give advice if necessary ...

Page 10: ...od for more information Instruction sheet ref TIS 120 The ducted air kit is connected to the 100mm spigot on the underside of the stove If the stove is installed directly on a hearth without any additional stands the ducted air supply will need to be set into the floor with appropriate protection It is recommended that a carbon monoxide alarm is installed in the same room as the appliance in accor...

Page 11: ...r both Air Cooled triple Skin Flue Kits Room Seal Insulated flue Kits that have been tested to AS NZS2918 2018 Horizontal lengths of flue must be kept to a minimum and should not be more in length than the flue diameter PRE LIGHTING CHECK Ensure that the baffle and upper baffle is fitted in the roof of the appliance For location and positioning see Fig 3 Check that the front fence is fitted correc...

Page 12: ...12 TIS 129 FITTING THE CENTRE STAND ...

Page 13: ...13 CLEARANCES PARALLEL POSITION COMBUSTIBLE WALLS CORNER POSITION Standard Clearance A 125mm B 276mm C 200mm D 544mm BAY BX Corner Clearance A 70mm B 418mm A B C D A A B ...

Page 14: ...05mm C 300mm D 70mm MIN DIMENSIONS TO WALL A 830mm B 905mm C 300mm D 70mm E 125mm BAY BX NON COMBUSTIBLE MATERIAL Minimum thickness 24mm Minimum thermal resistivity 0 026m2 K W Installed in accordance with AS NZS 2918 2018 3 3 2 DEFAULT HEARTH B B C C D D E D D A A TO WALL ...

Page 15: ...SIONS Minimum dimensions to wall CORNER HEARTH A 905mm B 70mm C 300mm BAY BX C A B B NON COMBUSTIBLE MATERIAL Minimum thickness 24mm Minimum thermal resistivity 0 026m2 K W Installed in accordance with AS NZS 2918 2018 3 3 2 ...

Page 16: ... top Increase from 1000 min until clear within 3000 of flue top DIMENSIONS IN MILLIMETRES Summary of minimum height of flue sytem exit requirements from AS NZS 2918 2018 More than 3000 More than 3000 600 min 600 min 3000 Any nearby structure Increase as necessary until nothing within 6000 of flue top ...

Page 17: ...17 150 1000 1000 1000 1000 25 600 Cowl Triple skin flue Flashing Optional Decorative Flue Solid OR Mesh Ceiling Ring Dropbox STANDARD DEFAULT TRIPLE SKIN FLUE KIT ...

Page 18: ...18 INSULATED ROOM SEAL FLUE KIT 185 1000 1000 1000 25 50 Single skin flue Room sealed flue adaptor Ceiling ring Heatshield Starter length flue Cowl Room sealed flue with locking band STANDARD FLUE KIT ...

Page 19: ...19 INSULATED ROOM SEAL FLUE KIT FULLY SEALED FLUE KIT 1000 1000 1000 1000 25 50 Cowl Ceiling ring Heatshield Starter length flue Room sealed flue with locking band ...

Page 20: ...20 COMPLIANCE DATA BAY BX COMPLIANCE DATA Compliance plate riveted onto rear panel ...

Page 21: ...21 BAY BX DIMENSIONS Plan View Store Stand Centre Stand Bench Stand Side view ...

Page 22: ...acket 14 010 XR087 Throat Plate Support Bracket 15 004 XR025 Side Brick Bracket 16 004 JT052 Rear Fixing Bracket 17 010 JT035 Table Top Plinth 18 004 XR055 Air Slide Cover 19 008 XR063 Air Box Upper Gasket 20 004 XR007 Air Control Slider 21 004 XR064 Control Rod 22 008 FFM056 Rod End 23 008 BR052 Felt Washer 24 010 XR022 Air Slide Control Handle 25 004 XR058 Clicker Assembly 26 008 XR062 Airbox Lo...

Page 23: ...and must be accompanied by proof of purchase Nothing in this guarantee shall affect your statutory rights EXCLUSIONS AND LIMITATIONS This Guarantee does not cover the following Charnwood will not be liable for any consequential loss or incidental loss damage or injury however caused This guarantee will become void if the appliance is not installed by a suitably qualified and is not installed in ac...

Page 24: ...your premier dealer ...

Reviews: