Users manual

Installation, Operating and Maintenance Instructions

ALASKA 120A and ALASKA 150A

Содержание ALASKA 120A

Страница 1: ...Users manual Installation Operating and Maintenance Instructions ALASKA 120A and ALASKA 150A ...

Страница 2: ... 120A 150A Contents 1 MANUFACTURER PRODUCT TYPE 3 2 USER MANUAL 5 2 1 STOVE DESCRIPTION 6 2 2 INITIAL IGNITION 7 2 3 LOADING FIREWOOD 7 2 4 CLEANING OF THE STOVE 8 2 5 BREAKDOWNS AND CAUSES 8 3 MOUNTING INSTRUCTIONS 9 4 TRANSPORT 10 5 INSTALATION INSTRUCTIONS 10 Lokaterm page 2 ...

Страница 3: ...N 13240 Smoke outlet diameter Ø 148 mm Nominal thermal power 6 kW Efficiency 80 5 CO emissions 13 O2 1000 mg m3 Dust emissions 22 mg m3 Exhaust smoke temperature 330 C Exhaust smoke volume 6 5 g s Flue draught at nominal power 12 Pa Outdoor air intake Ø 100 mm Dry weight 110 kg Dimensions of the stove Dia x Height Ф 460 mm x 1207 mm 120 A Ф 460 mm x 1507 150A Safety disatance sides and back 200 mm...

Страница 4: ...User Manual Installation Operating and Maintenance Instructions Stove Alaska 120A 150A Figure 2 Alaska 150 Lokaterm page 4 ...

Страница 5: ...uitable for burning natural firewood ex beech birch wood briquettes and briquettes made of brown coal Emission limitation It is forbidden to burn the following materials in stoves Impregnated or moist wood wood chips materials of organic origins hooves horns etc coal dust plastic waste or household waste paper and cardboard with exception when igniting fire Please note that burning any kind of was...

Страница 6: ...r must be in this position only during the heating up of the stove approximately the first 10 minutes of burning Normal operation area only the air inlet above the door is open secondary air This is an area within which the stove can be continuously used and the power can be regulated The handle may be located in any position but not in the heating up position Closed position of the air inlet LER ...

Страница 7: ...rohibited Nominal heat output 6 kW is generated when the regulator is set to Medium power position and there is aprox 2 0 kg of firewood inside of stove and the draught is at 12 Pa Some of the air which is heated up inside of stove is guided through the channels inside the stove onto the fire door glass where it performs a cleaning of the glass air brush cleaning principle Attention Certain types ...

Страница 8: ...fresh air inlet flap opened Is the air regulator handle opened Is the fresh air supply sufficient Is the firewood dry the stove doesn t heat up Is the air regulation handle in opened position the stove is overheating Is the air regulation handle in the heating up position the glass quickly becomes too sooty Firewood has to high moisture content Flue damper wasn t open enough The air regulation han...

Страница 9: ... or indirect air connection with fresh air Stove must not be installed In rooms where highly flammable and explosive substances or their mixtures are being manufactured processed or stored In rooms that are ventilated and do not have safety devices that prevent negative pressure In rooms that have no adequate air supply for stove to work properly Installation requirements Stove has to be installed...

Страница 10: ...d ash pan Check out functionality of movable parts front door etc Build outer air flaps into facade Mount smoke flap onto chimney funnel Connect chimney funnel Chimney thickness and insulation must be in accordance with country s and EU construction regulations Chimney must not apply additional pressure on the stove Minimum diameter of the chimney should be taken into consideration Measured values...