40i P - Installation/Operation - DRO installation - (28/32)
* Draw Graph:
Draws a graph with the points and errors entered. It is
recommended to check the graph to detect possible mistakes
made when entering data.
Note:
The maximum slope for the compensation graph is ±0.8 mm/m
.
3.6.4
Test mode.
It may be used to know system information such as software version, hardware version, software burning
date, etc.
Pressing the Test key displays the software and hardware versions, software recording date, checksum,
error history, etc.
Pressing Test again offers the chance to run different tests that are very useful for troubleshooting the
DRO itself or the encoder.
The Test mode is for the installer only and the access is protected with a password.
Password:
231202
Draw Graph