40i P - Installation/Operation - DRO installation - (27/32)
* Mandatory Home search. When set to YES, every time the
DRO is turned on, it forces a home search. It is recommended
to set it to YES when the DRO uses positioning error
compensation because if the compensated axis is not homed,
the compensation will not be applied.
* Type: It sets the reference system of the linear encoder:
NONE, NORMAL (INCREMENTAL) or DISTANCE-CODED.
When selecting DISTANCE-CODED, you must set the
engraving pitch of the linear encoder (20 µm, 40 µm or 100
µm) and the external multiplying factor (1, 5, 10, 25 or 50).
Exit and save data.
3.6.3.4
Compensation:
Choose the type of compensation to be used.
1- NONE.
2- LINEAR.
Choose LINEAR from the list, press Enter to validate it.
Press Edit to enter the compensation value. The following window is opened:
Even when working in inches, this value must always be in mm.
Enter the linear compensation value and press Enter.
3- MULTI POINT.
Choose MULTI-POINT from the list and press Enter to validate it.
Important
Before capturing data for an accuracy graph, a home
search must be carried out because the compensation will
not be applied until the home search is done. To use this
compensation, it is recommended to force a home search on
power-up.
Pressing the Edit button displays a table with 105 points and
their corresponding error values.
Error to be compensated = Master's actual position -
displayed position
There is no need to use all the points. The compensation point
must have at least one point with no error (error 0).
Different options are offered when the Function button is pressed:
* Exit:
To exit the screen saving the data.
Setup
Setup
Install
Comp.
Edit
Edit
Exit
Function