Power supplies
2.
Ref.1912
· 43 ·
DDS
HARDWARE
The non-regenerative power supply PS-25B4 has three switches on the
front and next to connector X1 (see figure) for selecting the external Ballast
resistor. If you have a model like this one, refer to the attached table to select
the right resistor model according to the setting of the switches that enables
the ·I
2
t· protection.
For the switch combination shown in the figure and verified in the table, the
ballast resistor selected would correspond to the ER+TH-18/1800.
NOTE.
This is the current model with three micro-switches to configure
the selection of the Ballast resistor installed.
T. H2/7
Layout of the Ballast resistor selector switches.
represents, in the figure, the moving element of the switch.
S3
S2
S1 RESISTOR
OFF
OFF
OFF
Internal
OFF
OFF
ON
ER+TH-18/1100
OFF
ON
OFF
ER+TH-18/1000+FAN
OFF
ON
ON
ER+TH-18/1800
ON
OFF
OFF
ER+TH-18/2200
ON
ON
OFF
RM-15 (discontinued)
ON
OFF
ON
ER+TH-18/1500+FAN or
ER+TH-18/2000+FAN
N ot e .
If y ou wis h to i nstal l a NON-
FAGOR resistor, please read below.
ON
ON
ON
ER+TH-18/1500+FAN or
ER+TH-18/2000+FAN
N ot e .
If y ou wis h to i nstal l a NON-
FAGOR resistor, please read below.
Model c
urrently
in the ca
talog
PS-25B4
ON
S1
S2
S3
WARNING.
When installing a NON-FAGOR resistor, only use this switch
setting when the power of your resistor is greater than any of the ones
shown in this cell of the tables provided by FAGOR. Ignoring this warning
MAY CAUSE THE DESTRUCTION of the resistor WITHOUT PRIOR
WARNING. Therefore, make sure to install your own protection system
when installing a NON-FAGOR resistor of lower power.
Example
S3
S2
S1 RESISTOR
OFF
ON
ON
ER+TH-18/1800
Summary of Contents for DDS APS-24
Page 1: ...DRIVE DDS Hardware manual Ref 1912...
Page 6: ...6 Ref 1912 DDS HARDWARE 6 I This page intentionally left blank...
Page 9: ......
Page 10: ......
Page 11: ......
Page 12: ......
Page 16: ...Ref 1912 DDS HARDWARE 16...
Page 20: ...Ref 1912 DDS HARDWARE 20...
Page 179: ...3 Drives Ref 1912 179 DDS HARDWARE...
Page 180: ...3 Drives Ref 1912 DDS HARDWARE 180...
Page 200: ...4 AUXILIARY MODULES Auxiliary modules Ref 1912 DDS HARDWARE 200...
Page 260: ...7 Cables Ref 1912 DDS HARDWARE 260...
Page 397: ...Sales models 12 Ref 1912 397 DDS HARDWARE 12 9 Order example F H12 21 Order example...
Page 404: ...13 Compatibility Ref 1912 DDS HARDWARE 404...
Page 405: ......