Power supplies
2.
94
Ref.1912
DDS
HARDWARE
· 34 ·
2.1 Non-regenerative power supplies
When referring to non-regenerative power supplies, we'll use PS-25B4 and
PS-65A. They all admit a voltage range between 400 to 460 V AC. They are:
The
PS-25B4
supplies 25 kW and includes an internal auxiliary 24 V DC
power supply for the control circuits of the modular drives. The over-voltage
and ballast alarm activation levels are the ones of the power supplies that
admit 460 V AC. The
PS-65A
supplies 65 kW and always needs an auxiliary
power supply APS-24 for the control circuits of the modular drives.
F. H2/1
Non-regenerative power supplies:
A.
PS-25B4,
B.
PS-65A.
A
Ri
L1 L2
Re L+
L+ Re Ri
L1
L3
L2
L3
B