Drives
3.
180
Ref.1912
DDS
HARDWARE
· 134 ·
X7 connector
X7. Status of the safety relay
This connector X7 of the modular drive is associated with the second contact
(N.C.,
N
ormally
C
losed) of an internal safety relay (with guided contacts).
The status of the relay (initially closed) may be acknowledged through the
two pins and a CNC, PLC or control panel, i.e. that the integrated safety
relay has actually opened or closed. These two terminals are identified at
the drive as AS1-AS2. The opening or closing of this relay depends on
whether 24 V DC are present or not at pin 2 «Drive Enable» of control
connector X2. For further detail on this connector, see section
Enable input and AS1-AS2 feedback output
in this manual.
The following table shows the values for gap, tightening torque, sections
and other data of aerial plug-in connector X7:
F. H3/74
X7 connector. External acknowledgment of the status of the integrated
safety relay.
T. H3/12
Pins of aerial plug-in connector X7. Technical data.
AXD|SPD|MMC
1.XX
2.XX
3.XX
Connector data
Nr of poles
2
2
2
Gap (mm)
5
5
5
Min./max. tightening torque (N·m) 0.5/0.6 0.5/0.6
0.5/0.6
Screw thread
M3
M3
M3
Min./max. section (mm²)
0.2/2.5 0.2/2.5
0.2/2.5
Rated current In (A)
12
12
12
Connection data
Length to strip (mm)
7
7
7
1
2
AS1
AS2
INTERNAL
RELAY CONTACT
x1
Summary of Contents for DDS APS-24
Page 1: ...DRIVE DDS Hardware manual Ref 1912...
Page 6: ...6 Ref 1912 DDS HARDWARE 6 I This page intentionally left blank...
Page 9: ......
Page 10: ......
Page 11: ......
Page 12: ......
Page 16: ...Ref 1912 DDS HARDWARE 16...
Page 20: ...Ref 1912 DDS HARDWARE 20...
Page 179: ...3 Drives Ref 1912 179 DDS HARDWARE...
Page 180: ...3 Drives Ref 1912 DDS HARDWARE 180...
Page 200: ...4 AUXILIARY MODULES Auxiliary modules Ref 1912 DDS HARDWARE 200...
Page 260: ...7 Cables Ref 1912 DDS HARDWARE 260...
Page 397: ...Sales models 12 Ref 1912 397 DDS HARDWARE 12 9 Order example F H12 21 Order example...
Page 404: ...13 Compatibility Ref 1912 DDS HARDWARE 404...
Page 405: ......