Drives
3.
180
Ref.1912
DDS
HARDWARE
· 160 ·
X1 connector
Compact drives internally generate the 24 V DC necessary for the internal
circuits.
In regular operation, this voltage is obtained from the power bus and from
line voltage of the mains when starting up the system.
It is a three-pin connector used to supply from mains the necessary start-up
energy.
The start-up process needs an internal module test prior to supplying
power to the upper terminals. Therefore, bear in mind the following
warning:
Current from mains phases to these lines L1 and L2 must be obtained from
a point before the contactor providing the three - phase power to the upper
connectors of the compact drive.
The following table shows the values for gap, tightening torque (wire entry
holes) and other data regarding the screw-on terminals of the plug-in
connector for X1 according to drive model:
F. H3/113
X1 connector. Line voltage INPUT (2-ph, VAC) from the mains.
1
2
3
L2
L1
LINE VOLTAGE
LINE VOLTAGE
200/240 V AC on ACD/SCD ... -L models
400/460 V AC on ACD/SCD/CMC models
WARNING.
This internal power supply must be powered through connector
X1 before carrying out any electrical maneuver.
T. H3/23
Aerial plug-in connector for X1. Technical data.
ACD|SCD|CMC
SCD
1.08|1.15|1.25|2.35|2.50
2.75
Connector data
Nr of poles
3
3
Gap (mm)
7.62
7.62
Min./max. tightening torque (N·m)
0.5/0.6
0.5/0.6
Screw thread
M3
M3
Min./max. section (mm²)
0.2/2.5
0.2/2.5
Rated current In
(A)
12
12
Connection data
Length to strip (mm)
7
7
1x
Summary of Contents for DDS APS-24
Page 1: ...DRIVE DDS Hardware manual Ref 1912...
Page 6: ...6 Ref 1912 DDS HARDWARE 6 I This page intentionally left blank...
Page 9: ......
Page 10: ......
Page 11: ......
Page 12: ......
Page 16: ...Ref 1912 DDS HARDWARE 16...
Page 20: ...Ref 1912 DDS HARDWARE 20...
Page 179: ...3 Drives Ref 1912 179 DDS HARDWARE...
Page 180: ...3 Drives Ref 1912 DDS HARDWARE 180...
Page 200: ...4 AUXILIARY MODULES Auxiliary modules Ref 1912 DDS HARDWARE 200...
Page 260: ...7 Cables Ref 1912 DDS HARDWARE 260...
Page 397: ...Sales models 12 Ref 1912 397 DDS HARDWARE 12 9 Order example F H12 21 Order example...
Page 404: ...13 Compatibility Ref 1912 DDS HARDWARE 404...
Page 405: ......