The following table shows the values for gap, tightening torque, sections of
the screws and other data of the plug-in connector for X2.
A door closes an enclosure that contains a DDS system with an RPS power
supply. The 24 V DC supplied at pin 1 of connector X2 may be taken to one
end of the door opening/closing switch and connect the other end to pin 4
“
PWM ENABLE
” of control connector X6. When the door is closed, 24 V DC
are applied to pin 4 “
PWM ENABLE
” hence letting the system run. When the
door opens, the switch opens and voltage is no longer applied to pin 4 of X6
hence opening the integrated safety relay. The system stops.
NOTE.
Do not take this example as a real application, but just as an
approach to the functionality of the “
PWM ENABLE
”.
X3 connector
The main integrated contactor “
LINE CONTACT
” (N.O.,
N
ormally
O
pen) is
closed through connector X3.
The status of the contactor will be acknowledged through pins 1 and 2 of this
connector and the CNC, PLC, control panel, etc. will confirm that the
integrated contactor has actually closed.
T. H2/33
Plug-in connector for X2. Technical data.
Connector data
RPS-80 | RPS-75 | RPS-45 | RPS-20
Nr of poles
3
Gap (mm)
5.00
Min./max. tightening torque (N·m)
0.5/0.6
Screw thread
M3
Min./max. section (mm²)
0.2/2.5
Rated current In (A)
12
Wire data
Length to strip (mm)
7
1x
INFORMATION.
In cases of micro-surges or total loss of mains power, this
module guarantees stable and maintained 24 V DC while the motors are
being stopped. This is an absolute must in order to comply with the EC
requirement for the machine.
i
Example regarding the 24 V DC of connector X2
MANDATORY.
Pins 3 and 4 MUST BE short-circuited to close the internal
contactor of the power supply and let the system run. Hence, get a 1 mm²
cable and jumper NS1 (pin 3) and NS2 (pin 4) externally to close the main
internal contactor. Remember that these pins do not come short-circuited
from the factory and if they are not short-circuited by the user, the DC BUS
will not be charged.
F. H2/45
Connector X3. Closing the main internal contactor “LINE CONTACT”.
X3 CONNECTOR
RPS-X
NS2
1
2
3
4
NS1
LINE CONTACT
Phoenix 7.62 mm
1
4
Jumper with 1 mm²
section cable
Summary of Contents for DDS APS-24
Page 1: ...DRIVE DDS Hardware manual Ref 1912...
Page 6: ...6 Ref 1912 DDS HARDWARE 6 I This page intentionally left blank...
Page 9: ......
Page 10: ......
Page 11: ......
Page 12: ......
Page 16: ...Ref 1912 DDS HARDWARE 16...
Page 20: ...Ref 1912 DDS HARDWARE 20...
Page 179: ...3 Drives Ref 1912 179 DDS HARDWARE...
Page 180: ...3 Drives Ref 1912 DDS HARDWARE 180...
Page 200: ...4 AUXILIARY MODULES Auxiliary modules Ref 1912 DDS HARDWARE 200...
Page 260: ...7 Cables Ref 1912 DDS HARDWARE 260...
Page 397: ...Sales models 12 Ref 1912 397 DDS HARDWARE 12 9 Order example F H12 21 Order example...
Page 404: ...13 Compatibility Ref 1912 DDS HARDWARE 404...
Page 405: ......