Remote modules.
CNC 8060
CNC 8065
7.
RCS-S-4F4
AO (SERCOS-II
PROTOCOL).
C
onne
cti
on.
·144·
(R
EF
: 1906)
Module identification.
Address (node) of the element within the bus.
Sercos-II bus setting (transmission speed and optical power).
Switch.
Transmission speed.
·1·
·2·
Off
Off
2 Mbps.
ON
Off
4 Mbps.
Off
ON
8 Mbps.
ON
ON
16 Mbps.
Switch.
Optical power depending on cable length.
·3·
·4·
Off
Off
1 to 4
Cable shorter than 15 meters.
Recommended cable: SFO / SFO-FLEX
ON
Off
5 to 6
Cable between 15 and 30 meters.
Recommended cable: SFO-FLEX
Off
ON
7
Cable between 30 and 40 meters.
Recommended cable: SFO-FLEX
ON
ON
8
Cable longer than 40 meters.
Recommended cable: SFO-V-FLEX
Nodes are identified with the 16-position rotary switch
(thumbwheel) "Address" (also called "Node_Select") and for
the RCS-S modules also with parameter SERCOUUNTID.
This switch selects the address occupied by each of the
elements integrated into the Sercos connection. The CNC
does not have the switch; it is pre-configured to always occupy
position ·0· at the bus. The nodes must occupy consecutive
positions starting at ·1·. In order for any change at the
"Address" switch to be assumed, the corresponding node must
be reset and the CNC powered off and back on.
Switches ·1· and ·2· indicate the Sercos transmission speed
(baudrate).
Switches ·3· and ·4· set the Sercos power or the intensity of
the light going through the optic fiber. The optical power value
depends on the total length of the cable being used. Set these
values with the same values used by the CNC and the drives.
Assigning other optical power values, e.g. a value of 6 for a
length of 3 m, can cause communication errors due to fiber
optic signal distortion.
ON
OFF
S39
Summary of Contents for 8025 M CNC
Page 1: ...Ref 1906 8060 8065 CNC Remote modules...
Page 8: ...BLANK PAGE 8...
Page 14: ...BLANK PAGE 14...
Page 16: ...BLANK PAGE 16...
Page 18: ...BLANK PAGE 18...
Page 20: ...BLANK PAGE 20...
Page 24: ...BLANK PAGE 24...
Page 26: ...BLANK PAGE 26...
Page 28: ...BLANK PAGE 28...
Page 30: ...Remote modules CNC 8060 CNC 8065 1 PREVIOUS INFORMATION 30 REF 1906...
Page 32: ...Remote modules CNC 8060 CNC 8065 2 HARDWARE STRUCTURE 32 REF 1906...
Page 177: ...Remote modules CNC 8060 CNC 8065 177 User notes REF 1906...
Page 178: ...Remote modules CNC 8060 CNC 8065 178 User notes REF 1906...
Page 179: ...Remote modules CNC 8060 CNC 8065 179 User notes REF 1906...