Remote modules.
CNC 8060
CNC 8065
RIOR REMOTE MODULES.
(CANOPEN
PROTOCOL).
6.
Con
nection of th
e anal
og inp
uts/ou
tp
uts
an
d th
e PT
10
0
inpu
ts.
·125·
(R
EF
: 1906)
6.7
Connection of the analog inputs/outputs and the PT100 inputs.
·I48· connector pinout.
Cable characteristics.
Use shielded twisted cable, AWG 16 to AWG 24 gage. The unshielded portion of the wires
of an unshielded cable cannot be longer than 75 mm.
PT100 sensor connection.
The module allows connecting sensors with a 2-wire interface.
Plug-in part 8x2 pin two-level male Phoenix Contact minicombicon
(3.5 mm pitch). Rated current; 8 A.
Pin.
Signal.
Function.
1
GND_AO1
Reference signal. Analog output 1.
2
GND_AO2
Reference signal. Analog output 2.
3
AO1+
Analog output 1.
4
AO2+
Analog output 2.
5
GND_AO3
Reference signal. Analog output 3.
6
GND_AO4
Reference signal. Analog output 4.
7
AO3+
Analog output 3.
8
AO4+
Analog output 4.
9
GND_AI1
Reference signal. Analog input 1.
10
GND_AI2
Reference signal. Analog input 2.
11
AI1+
Analog input 1.
12
AI2+
Analog input 2.
13
GND_PT100_1 Reference signal. Input PT100 1.
14
GND_PT100_2 Reference signal. Input PT100 2.
15
Input PT100 1.
16
Input PT100 2.
1
15
2
16
Always connect the shield of the cable to the ground plate of the module itself.
Shield.
Ground plate.
Connection of 2 wires.
GND_PT100_1
Summary of Contents for 8025 M CNC
Page 1: ...Ref 1906 8060 8065 CNC Remote modules...
Page 8: ...BLANK PAGE 8...
Page 14: ...BLANK PAGE 14...
Page 16: ...BLANK PAGE 16...
Page 18: ...BLANK PAGE 18...
Page 20: ...BLANK PAGE 20...
Page 24: ...BLANK PAGE 24...
Page 26: ...BLANK PAGE 26...
Page 28: ...BLANK PAGE 28...
Page 30: ...Remote modules CNC 8060 CNC 8065 1 PREVIOUS INFORMATION 30 REF 1906...
Page 32: ...Remote modules CNC 8060 CNC 8065 2 HARDWARE STRUCTURE 32 REF 1906...
Page 177: ...Remote modules CNC 8060 CNC 8065 177 User notes REF 1906...
Page 178: ...Remote modules CNC 8060 CNC 8065 178 User notes REF 1906...
Page 179: ...Remote modules CNC 8060 CNC 8065 179 User notes REF 1906...