English
English
SPECIAL KEYS
(not active)
-
The key can be personalized with one
of the following functions:
- II choice (second function, dispensing of a second beverage
- disable (disables key);
- stop.
Service boiler pressure
– indicates the boiler pressure: 1.3 ÷ 1.4
bar (18 ÷ 20 psi)
Unit temperature
– indicates the unit temperature, from 70 to 110
° C and from 158 to 230 ° F
TURBOSTEAM -
includes 2 sub-menus
Stop steam temperature
– indicates the automatic stop steam
temperature (Autosteam). Can be set between a minimum
of 40 and a maximum of 85° C (104 – 185 ° F).
Regolator
-
flow regolator: YES/ NO.
YES
- the machine has the flow regolator on the
turbosteam circuit
.
NO
- the machine does not have the flow regolator; is
therefore possible to set 4 different levels of emulsion.
See paragraph
"Autosteam"
on the following pages.
MEASURING UNIT
– includes 2 sub-menus
Temperature
– can be set to °C Celsius centigrade or °F Fahrenheit
degrees.
Pressure
– can be set to bar or psi.
N. grounds
– refers to number of grounds, from 0 (external
container) to 50.
REGENERATION -
includes the parameters for the softner
regeneration: liters of resin (da 0,1l a 25l), hardness (da 0 a 45 °F)
Customer programming
– YES/ NO
Programming block -
programming block: YES/NO.
With the function active (YES) the use of the programming keyboard
is allowed with the technician card; “
i
” key remains always active.
Payment system
– permits configuration of payment system,
when connected.
7. Configuration menu
+
u
u
!
CONFIGURATION
SPECIAL KEYS
ser. boiler press.
1,4 bar
Group temp.
070°C
TURBOSTEAM
MEASUREMENT UNITS
N° ground
030
SOFTNER REGENER.
+
u
u
!
CONFIGURATION
Custumer prog.
NO
progr. block
NO
Paym. system
OFF
Buzzer
YES
WASHING OPTIONS
Standard data
NO
DATA IN/OUT
+
u
u
!
CONFIGURATION
Archive reset
NO
MAINTENANCE
Buzzer
- The machine buzzer can be enabled so that a beep is heard
when the keys are pressed.
WASHING OPTIONS -
See paragraph
"Washing options"
on the
following pages.
Standard data
– loads standard data. YES/NO
DATA IN/OUT
– contains three entries:
Key
– indicates the key number from 0 to 60.
Data
IN transfer from smart card to machine. OUT transfer from
machine to smart card.
TX/RX
– to start data transfer
Archive reset
– zeros the error log (Wash 1 Archive and
malfunctions archive) stored on the machine: YES/NO
MAINTENANCE -
contains five entries to setting maintenance
parameters:
Max cycles
- the number of cycles initially set: 40,000.
Max days
- the number of days initially set: 185.
N° cycles
- the number of cycles remaining before the next
maintenance session.
N° days
-
the number of days remaining before the next
maintenance session.
Reset
-
options are:
NO
, countdown of cycles and days remaining
before the next maintenance session.
YES
, the settings for number of cycles (40,000)
and remaining days (185) are reset
OFF
, all controls for programmed maintenance
are disabled, and the “N. cycles” and “N. days”
counters are zeroed.
Summary of Contents for X2 GRANDITALIA
Page 4: ...X2 GRANDITALIA 6 3 12 16 6a 13 14 15 17 23 35 39 18 1 26 5...
Page 5: ...X2 GRANDITALIA CK 6 3 12 16 6a 13 14 15 17 23 35 39 18 1 26 5 Chc...
Page 24: ......
Page 38: ...English English...
Page 46: ...English English...
Page 53: ...English English...
Page 71: ...English English...
Page 89: ...English English...
Page 95: ...English English FC3 1 17 Weighting Weighting phase Standby...