24
ENGLISH
Bar length
Installed
accessories
2 m
2,5 m
3 m
3,5 m
4m
4 m
(with
coupling
)
4,5 m
5 m
5 m
(with
coupling
)
No
accessories
1
1
2
2
2
3
3
3
3
Lights
1
1
2
2
2
3
3
3
Lights / Skirt
1
1
2
3
3
3
3
Lights / Foot /
Skirt
1
2
2
3
3
3
3
Lights / Foot
1
2
2
3
3
3
3
Foot
1
1
2
3
3
3
3
Skirt
1
1
2
2
3
3
3
Skirt/Foot
1
2
2
3
3
3
3
Table 4
Bar length
Installed accessories
5 m
(without
coupling)
5 m
5,5 m
6 m
6,5 m
7 m
7,5 m
8 m
No accessories
4
4
5
5
5
5
5
6
Lights
4
4
5
5
5
5
6
6
Lights / Skirt
4
5
5
6
6
6
6
Lights / Foot / Skirt
5
5
5
5
6
6
Lights / Foot
4
5
5
5
5
6
6
6
Foot
4
5
5
5
5
5
6
6
Skirt
4
5
5
5
5
6
6
Skirt/Foot
5
5
5
5
5
6
Table 5
13. DEFAULT SELECTION TABLES (
dF
parameter)
The purpose of the two following tables is to determine, depending on the length of the bar and the number and type of accessories installed,
the correct default value to set in the first Basic programming function.
Table 4 refers to the balance spring for bar lengths equal to or shorter than 5 m and featuring a profile corresponding to the one in Fig. 8
on page 25, ref.
a
(“S” profile).
Table 5 refers to the balance spring for bar lengths equal to or longer than 5 m and featuring a profile corresponding to the one in Fig. 8 on
page 25, ref.
b
(“L” profile).
The key to symbols for identifying the fixing holes based on the number indicated in the tables is shown in Fig. 30.
Summary of Contents for B680H
Page 1: ...B680H ...
Page 2: ......
Page 4: ......
Page 151: ...27 a b c d e f g h Fig 17 L ...
Page 152: ...28 Fig 18 a b a b d Fig 19 c 1 2 Fig 20 ...
Page 153: ...29 a b Fig 21 d e f c ...
Page 156: ...32 Fig 31 a b c d e ...
Page 157: ...33 Fig 32 f g ...
Page 158: ......
Page 163: ...5 1 2 Fig 18 ...
Page 164: ......
Page 165: ......