8
ENGLISH
Dip 1 Dip 2 Dip 3 Dip 4
Pair
no.
Type
ON
OFF
OFF
OFF
1° Pair
CLOSE
photocells
ON
OFF
OFF
ON
2° Pair
ON
OFF
ON
OFF
3° Pair
ON
OFF
ON
ON
4° Pair
ON
ON
OFF
OFF
5° Pair
ON
ON
OFF
ON
6° Pair
ON
ON
ON
OFF
7° Pair
ON
ON
ON
ON
Single
OPEN
PULSE
DIP-SWITCH
TX
DIP-SWITCH
RX
SAME
ADDRESS
4.1.2 Connecting BUS photocells
Up to 8 pairs of photocells can be connected to the E680 control board
using BUS technology. The connection must be made in parallel,
on terminal board J6, using a single power/communication line, as
shown in Fig. 27.
BUS photocells do not require a matching polarity
connection.
The 8 pairs of photocells feature the following functions:
Pairs of closing photocells:
max 7
Pairs of OPEN pulse photocells:
max 1
After positioning the BUS technology photocells, it is necessary
to proceed with selecting the address for each pair using various
combinations of the
DIP-SWITCHES
located on each photocell.
Set the SAME DIP-SWITCH ADDRESS chosen both on
the transmitter and receiver of the same pair.
Ensure that two or more pairs of photocells do not have
the same address. If no BUS accessories are used, leave
terminals 1 and 2 free.
The following table describes how to set the dip-switches located
inside the transmitter and receiver of the BUS photocells.
Addressing BUS photocell PAIRS
To allow operation of the installed BUS accessories,
store them on the board as described in paragraph 5.3.
4.2 Terminal board J2 (outputs)
OUT 1 - Output 1 open-collector GND (terminal 13):
The output can
be set in one of the functions described in the Advanced Configuration
(par. 6). The default value is
04
- Beam OPEN or in PAUSE
.
Maximum load: 24 VDC with 100 mA.
OUT 2 - Output 2 open-collector GND (terminal 15):
The output can
be set in one of the functions described in the Advanced Configuration
(par. 6). The default value is
03
- CLOSED BEAM.
Maximum load:
2
4 VDC with 100 mA.
OUT 3 - Output 3 open-collector GND (terminal 17):
The output can
be set in one of the functions described in the Advanced Configuration
(par. 6). The default value is
19
- WARNING LAMP.
Maximum load:
24 VDC with 100 mA.
OUT 4 - Relay output 4 (terminals 19, 20, 21):
The output can be
set in one of the functions described in Advanced Configuration (par.
6). The default value is
0 1
- BEAM ILLUMINATION.
Maximum
load: 24 VDC with 800 mA.
4.3
Terminal board J3 (external flashing lamp)
LAMP:
to these terminals you can connect a 24VDC FAACLED
external flashing lamp.
The integrated flashing traffic light must be
connected independently to connector J15.
The 24V FAACLIGHT with incandescent lamp cannot be
connected to the J3 connector
4.4 Terminal board J4 (loop detector)
LOOP 1:
magnetic loop LOOP 1 (OPEN, terminals 24-25): for
OPENING.
LOOP 2:
magnetic loop LOOP 2 (SAFETY/CLOSE, terminals 26-27):
for
SAFETY/CLOSING.
4.5 Connector J5 (Motor)
Rapid connector for connecting the motor.
4.6 Connector J7 (Encoder)
The B680H barrier is equipped with a device for detecting the opening
angle/bar position to ensure greater anti-crushing safety thanks to
the possibility of reversing the direction of movement the moment in
which an obstacle is detected. This device interfaces with the board
through connector J7.
4.7 Connector J10 (Radio)
Used for the rapid connection of the Minidec, Decoder and RP / RP2
Receivers (see Fig. 28). If a 2-channel receiver is used, like the RP2,
it will be possible to directly command automated system OPEN and
CLOSE from a 2-channel radio control. If a 1-channel receiver is used,
like the RP, it will only be possible to command OPEN.
Connect the accessory with the components side facing the main
strip of the board.
Boards should be inserted and removed ONLY after
having cut off electrical power
4.8 Connector J11 (Beam break-out sensor)
Designed for connecting the break-out sensor for the pivoting beam
(if present). The sensor is optional. If it is not present,
do not remove
the installed jumper.
4.9 Connector J12 (Emergency battery)
This connector is for connecting a battery (optional) for ensuring
automated system operation in case of temporary cut off of the main
power supply.
4.10 Connector J13 (36VDC Power Supply)
This factory-wired connector powers the E680 board
4.11
Connector J15 (flashing traffic light)
This connector is for connecting the flashing traffic light built into
the barrier head. The flashing traffic light visually signals barrier
movement and, if needed, regulate access to the property using
traffic light signals.
5. PROGRAMMING
The E680 board features 3 programming levels that make it entirely
configurable and allow it to adapt the logics to any use.
Each of the three levels can be accessed through a specific key
combination.
Summary of Contents for B680H
Page 1: ...B680H ...
Page 2: ......
Page 4: ......
Page 151: ...27 a b c d e f g h Fig 17 L ...
Page 152: ...28 Fig 18 a b a b d Fig 19 c 1 2 Fig 20 ...
Page 153: ...29 a b Fig 21 d e f c ...
Page 156: ...32 Fig 31 a b c d e ...
Page 157: ...33 Fig 32 f g ...
Page 158: ......
Page 163: ...5 1 2 Fig 18 ...
Page 164: ......
Page 165: ......