12
ENGLISH
DL1 LED description (Red)
On
At least one of the inputs (safeties, OPEN pulse) is
engaged or active
Off
No OPEN input is active and no safety device is
engaged
DL2 LED description (Green)
On
fixed
Normally active (LED on even if there are no devices
connected)
Off
BUS-2EASY line short-circuited (flash every 2.5
sec.)
Rapid
flashing
An error has been detected in the BUS-2EASY
connection; repeat the acquisition procedure. If the
error persists, check that:
•
the system does not have more than one
accessory with the same address (see also
instructions regarding the accessories)
•
make sure there is no calling error (number of
devices connected is greater or less than that
stored during setup)
6.
Advanced Configuration
To access Advanced Configuration, press
F
and, while holding it,
also press
+
:
•
when
+
is released, the number of the first available function
will appear
•
when
F
is also released, the value is displayed, and can be
changed using
+
and
-
•
pressing
F
again, and holding it, the name of the next parameter
will be displayed; when released, the value can be changed
using
+
and
-
•
once the last function has been reached, pressing
F
makes it
possible to either save the previously changed parameters or exit
without saving the changes; the display will go back to showing
the status of the inputs.
ADVANCED CONFIGURATION
Display Function
Default
FO
Opening motor power
Adjusts the thrust of the motor during the ope
-
ning phase.
00
Minimum power
50
Maximum power
40
FC
Closing motor power
Adjusts the thrust of the motor during the closing
phase.
00
Minimum power
50
Maximum power
40
PF
Pre-flashing
This parameter is used to activate the flashing
lamp for 5 seconds before the selected
movement.
no
disabled
OC
before each movement
CL
before each closing movement
OP
before each opening movement
PA
only at the end of the pause
no
Display
Function
Default
tP
Pre-flashing time
Pre-flashing time expressed in seconds.
00
minimum pre-flashing
10
maximum pre-flashing
00
oc
Sensitivity of obstacle during closing
This determines the sensitivity to an obstacle
before reversing takes place.
0 1
Minimum sensitivity
50
Maximum sensitivity
0 1
o 1
Output 1
Setting this function makes it possible to modify
the signal type of output 1, allowing high
connection flexibility with external devices.
00
Failsafe
0 1
TYPE 1 BEAM ILLUMINATION
(output
active when beam closed, disabled
with bar open or paused, intermittent
when moving).
Use only with output
4!
02
DISABLED
03
Beam CLOSED
04
Beam OPEN or in PAUSE, it goes off
during closing pre-flashing.
05
Beam in OPENING MOVEMENT,
including pre-flashing.
06
Beam in CLOSING MOVEMENT,
including pre-flashing.
07
Beam STATIONARY
08
Beam in EMERGENCY mode
09
LOOP1 engaged
10
LOOP2 engaged
1 1
OPEN for E680 slave
12
CLOSE for E680 slave
13
Beam RELEASED
14
Not used
15
Not used
16
FCA engaged
17
FCC engaged
18
Not used
19
WARNING LAMP (on during opening
and pause, flashing when closing, off
when the automated system is closed)
04
Summary of Contents for B680H
Page 1: ...B680H ...
Page 2: ......
Page 4: ......
Page 151: ...27 a b c d e f g h Fig 17 L ...
Page 152: ...28 Fig 18 a b a b d Fig 19 c 1 2 Fig 20 ...
Page 153: ...29 a b Fig 21 d e f c ...
Page 156: ...32 Fig 31 a b c d e ...
Page 157: ...33 Fig 32 f g ...
Page 158: ......
Page 163: ...5 1 2 Fig 18 ...
Page 164: ......
Page 165: ......