Changes to the configuration parameters become
effective immediately, while final storage occurs
only upon exiting configuration and returning to the
automated system status display. If the equipment is
powered down before returning to the automated system
status display, all changes made will be lost.
5.1
Basic configuration
To perform BASIC programming:
1.
Press and hold button
F
; the name of the first function is
displayed.
2.
Release the button; the function value is displayed and can be
modified using the + and - buttons.
3. Press and hold
F
again; the name of the following function is
displayed, and so on.
The last function St lets you choose whether to save the configuration
made (
Y
) or exit without saving (
no
)
. Later, the display will resume
showing the automated system status
You can go to St at any time. To exit programming,
simultaneously press F and -.
BASIC CONFIGURATION
Display
Function
Default
dF
Loading predefined parameter sets
00
Neutral condition
0 1
Minimum mass
06
Maximum mass
Before automated system start-up, you must
set the correct value, directly correlated to the
length of the beam and the number and type
of accessories installed. To determine said
value, refer to Tables 4 and 5 on page 24
WARNING: Setting a mass default
lower than the one actually
installed could cause irreversible
damage to the bar and barrier
structure.
If you do not wish to make any programming
changes, leave the value
00
, otherwise
selecting a value involves loading the chosen
predefined parameters set (see paragraph
5.2).
00
At
Currently loaded default
This menu indicates the currently loaded
default setting.
Given that parameter
dF
has
00
as the
predefined value (in order to provide a neutral
access condition to the parameters), using the
value in this menu makes it possible to identify
the currently configured default setting.
Read-only parameter
06
Display
Function
Default
bu
BUS accessories menu
For functions associated with this parameter
see paragraph 5.3
no
LO
Operating logics
A
Automatic
A 1
Automatic 1
E
Semi-automatic
P
Parking
PA
Automatic parking
Cn
Condo
CA
Automatic condo
C
Dead-man
CU
Custom
E
PA
Pause time
Is effective only if an automatic logic is
chosen; the value can be set from
O
to
59
sec. in one second steps. Next, the
display changes to minutes and tenths of a
second (separated by a decimal point) and
time is adjusted in 10-second steps up to the
maximum value of
4.1
minutes.
e.g. if the display shows
2.5
, the pause time
will be 2 minutes and 50 seconds.
20
So
Opening speed
Adjusts the barrier opening speed.
00
Minimum speed
1 0
Maximum speed
WARNING: Setting an excessive speed
could cause irreversible damage to the
beam and barrier structure.
10
Sc
Closing speed
Adjusts the barrier closing speed.
00
Minimum speed
1 0
Maximum speed
WARNING: Setting an excessive speed
could cause irreversible damage to the
bar and barrier structure.
02
L 1
Loop 1
Activating this parameter, any loop that is
connected to the Loop 1 input will serve as
an OPEN function.
Y
Loop 1 enabled
no
Loop 1 disabled
Note: Should this function be disabled, the
detection status of the loop will in any case
remain available on one of the two outputs,
if configured (see parameters
o1
...
o4
in
Advanced Configuration)
no
Summary of Contents for B680H
Page 1: ...B680H ...
Page 2: ......
Page 4: ......
Page 151: ...27 a b c d e f g h Fig 17 L ...
Page 152: ...28 Fig 18 a b a b d Fig 19 c 1 2 Fig 20 ...
Page 153: ...29 a b Fig 21 d e f c ...
Page 156: ...32 Fig 31 a b c d e ...
Page 157: ...33 Fig 32 f g ...
Page 158: ......
Page 163: ...5 1 2 Fig 18 ...
Page 164: ......
Page 165: ......