EXPERT Standard Series User Manual
64
Parameter
code
Parameter
name
Setting range
Mini
munit
Default
value
Mod
ition
F8.10
Maximum given
quantity
(F8.08)~100.0%
(The percentage of maximum given
quantity and reference value
10V;20mA)
0.1% 100.0%
○
F8.11
Corresponding
feedback quantity of
maximum given
quantity
0.0~100%
(The percentage of corresponding
feedback quantity of maximum given
quantity and reference value
10V;20mA)
0.1% 100.0%
○
F8.12
Proportional gain KP 0.000~9.999
0.001
2.000
○
F8.13
Integral gain Ki
0.000~9.999
0.001
0.100
○
F8.14
Sampling period
0.001~50.000s
0.001s 0.100s
○
F8.15
Deviation limit
0.0~20.0%
(Corresponding closed loop given
value)
0.1%
2.0%
○
F8.16
Closed loop
regulating
characteristic
0:Positive
1:Negative
Note:Relation between given speed
and rotate speed
1
0
×
F8.17
Sleeping frequency 0.00Hz~550.0Hz
0.01Hz
0
*
F8.18
Closed loop preset
frequency
0.00~550.0Hz
0.01Hz 0.00Hz
○
F8.19
Closed loop preset
frequency hold time 0.0~3600s
0.1s
0.0s
×
F8.20
Multistage closed
loop given 1
0.00~10.00V
0.01V 0.00V
○
F8.21
Multistage closed
loop given 2
0.00~10.00V
0.01V 0.00V
○
F8.22
Multistage closed
loop given 3
0.00~10.00V
0.01V 0.00V
○
F8.23
Multistage closed
loop given 4
0.00~10.00V
0.01V 0.00V
○
F8.24
Multistage closed
loop given 5
0.00~10.00V
0.01V 0.00V
○
F8.25
Multistage closed
loop given 6
0.00~10.00V
0.01V 0.00V
○
F8.26
Multistage closed
loop given 7
0.00~10.00V
0.01V 0.00V
○
F8.27
Multistage closed
loop given 8
0.00~10.00V
0.01V 0.00V
○
F8.28
Multistage closed
loop given 9
0.00~10.00V
0.01V 0.00V
○