EXPERT Standard Series User Manual
25
Chapter2 Installation and Wiring of Drive
2.1 Installation environment of drive
2.1.1 Installation environment condition
(1) The drive shall be installed indoors of perfect ventilation, and the
environment temperature shall be in the range of -10℃~40℃, in case that the
temperature exceeds 40℃, the external air-blast cooling or derating shall be
used.
(2) Avoid being installed in location where suffers from the sun, dust, floatation
fiber and metallic power
(3) Never to be installed in location where corrosive and explosive gas has
(4) The humidity shall be lower than 90%RH, no condensation
(5) The drive shall be installed in the location where the plane fixed vibration is
less 5.9 m/s 2
(6) The drive had better be kept far away from the electro-magnetic interference
device
2.1.2 Installation direction and space
(1) Shall be installed vertically usually
(2) The installation space and min distance are shown as diagram2-1
(3) As shown in diagram 2-2, there shall be baffler mounted among them, when
several drives are installed vertically.
B
Fan efficiency exhaust
B
A
A
PRG
M-F
ENT
RUN
STOP
RESET
Hz
A
V
RUN
MON
QUICK
REV/FWD
Guide plate
in
ve
rte
r
in
ve
rte
r
Diagram2-1 Installation space