Dedicated Move
The Dedicated Move is designed to provide a method, available from any mode, to Move to a
specified position. The Dedicated Move has priority in all operating modes. For example if the
current Operating Mode is Alternate and the motion type is Analog Position when the Dedicated
Move Input Function goes active the Alternate Move will become active, even though Digital
Input Mode is not active. When the Alternate Mode Input Function is switched back to inactive
the Mode will revert back to Analog Position.
Disable drive upon completion of dedicated move
check box allows a method of automatic shut
down at the completion of the move. The drive must be re-enabled to resume operation.
Note:
The Dedicated Move Position is an absolute position, therefore a Home cycle must be
completed (Homed Output Function on), before a Dedicated Move will be allowed to execute.