Tritex 1 Installation and Setup
70
09/27/12
PN: 27666
Exlar Corporation
Rev. M
952-500-6200M
Download using the down arrow
Establishes communication and downloads all the drive parameters from the PC to the drive
and stays online.
Now that the screens are indicating the drive parameter values, the drive can be programmed
following the same steps as in the Offline operation.
Changing drive parameters:
When a parameter on the screen is changed, the new value is
generally not sent down to the drive, with the exception of parameters on the Jog tab, and
screens used for calibration such and Tuning and the analog tabs. When a parameter is
changed it can be sent to the drive by double clicking on the parameter or if a right click is
performed an option dialog will pop up with action options for the parameter.
Important:
When a parameter has been edited the focus must be removed from the parameter
for the value to be accepted, either tab off the parameter or click on another parameter or press
enter. If this is not done the value will not be downloaded.
IMPORTANT-
Saving parameters in the drive: Parameters are
not
saved into the drives non-
volatile memory unless a download is performed. Individual Parameter changes only write to
non permanent RAM memory, this means a download must be performed or the parameters will
revert back to their previous value when logic power is cycled.