![Exlar Tritex Installation Manual Download Page 107](http://html1.mh-extra.com/html/exlar/tritex/tritex_installation-manual_2450859107.webp)
Tritex 1 Installation and Setup
107
09/27/12
PN: 27666
Exlar Corporation
Rev. M
952-500-6200M
User Units
The first step in setting up a new application is to select the user units. On the main menu bar
select Drive/Units and the following page will be displayed.
Distance Scaling:
The distance scaling factor can be setup for a linear actuator with an inch per motor rev
conversion factor, rotary actuator with an output rev per motor rev conversion factor or for a
custom actuator with a user units per motor rev conversion factor.
For linear actuators, this distance scaling factor is the actuators lead. (.1, .2, .4 or .5) For Rotary
applications, this is the gear reduction. (0.25 for 4:1, 0.1 for 10:1, 0.04 for 25:1 etc)
Select the units for distance, velocity and acceleration units the application will work in. Select
the precision to display as and enter the text that will actually be displayed on the pages. The
inch to millimeter and inch meter conversions are done automatically based on the Inches per
Motor Rev conversion. Output Revs and Degrees are calculated automatically based on the
Output Revs conversion factor. For custom units User Units are calculated base on the User
Unit per motor rev scale factor.