For Rotary applications with a 10:1 gear reduction select Output Revs.
Distance scaling is 0.1 Output Revs per Motor Rev
For Distance Units select Output Revs, Output Degrees. For Velocity select units such
OutputRevsPerMinute, OutputRevsPerSecond, DegreesPerMinute, or DegreesPerSecond. For
Acceleration units select OutputRevsPerSecondPerSecond or DegressPerSecondPerSecond.
Then type in the text to displayed for each unit.
When the working distance is other than Inches, mm, m, Output Revs or Degrees use the
UserUnit Distance scaling.
For other user units such as Cycle and Cycles/ sec, select UserUnits for Distance scaling and
enter the conversion for Cycles per Motor Rev, such 0.123346, Select UserUnits as the working
unit, select the precision for display and the text to be displayed such CYC. For velocity working
units select UserUnitsPerSecond or UserUnitsPerMinute. For Acceleration select
UserUnitsPerSecondPerSecond.