Tritex 1 Installation and Setup
84
09/27/12
PN: 27666
Exlar Corporation
Rev. M
952-500-6200M
Host Mode
Host Mode can only be selected via Modus commands. Host Mode allows the same motion
types as the other modes plus Host Position, Velocity and Torque.
Special Condition Motion
The Special Condition Logic allows certain motion types to be activated from Input Functions
even if Digital Input Mode is not the currently selected mode.
Dedicated Move:
If the Dedicated Move Input Function is activated from an Input or Modbus it
will override any active motion from any mode, except a Home motion. As soon as the function
is deactivated the motion type will revert to the active mode. A Home cycle must be completed
(Homed Output Function on) before a Dedicated Move will be allowed.
Home Cycle:
If a Home cycle has not been completed a Home can be initiated from an Input or
Modbus address even if Digital Inputs is not the active Mode. Once the Homed Output Function
is active an subsequent Home cycle can only be activated when Digital Input Mode is active.
Jog:
If the Allow Jog Override on Default Operation Mode or Allow Jog Override on Alternate
Operation Mode check box is checked Jog motion will override the active motion when the
Digital Input Mode is not active. (See Startup section of the System Startup page for details)