1.1. HMI panel................................................................................................................ 6
1.2. Display icons..........................................................................................................7
2. Operation, access codes and selection of language
2.2. Access codes for technician and service menus............................................. 10
2.3. IMPORTANT when servicing............................................................................... 11
Menu 3.2 - Selecting language............................................................................13
Menu 3.2.1 - Setting date and time..................................................................... 13
Menu 3.2 - Reset settings....................................................................................13
Menu 3.2 - Reload database................................................................................14
Menu 3.6 - Web server......................................................................................... 14
Menu 3.7 - Backup/restore.................................................................................. 15
3. Starting up the unit for operation
Start configuration..........................................................................................17
Menu 3.4 - Accessories..................................................................................18
Menu 3.4 Connecting heating and cooling units ........................................... 19
Menu 1 - Selecting operating mode................................................................... 21
Menu 3.1.1 - Operating settings - Air regulation............................................... 22
Menu 3.1.1 - Operating settings Balance.......................................................25
Menu 3.1.1.5 Regulators ...............................................................................26
Menus 3.1.1.1.1 to 3.1.1.1.4 Setting the selected indoor air quality levels..... 26
Menu 3.1.1.1.x - Air set point ........................................................................ 26
Menu 3.1.1.1.x - Temperature set point ........................................................ 26
Menu 3.1.1.1.x - Absolute / Relative temperature .........................................27
Menu 3.1.1.1.x - Cooling relative start .......................................................... 27
Menu 3.1.1.1.x - Heating relative start .......................................................... 27
Menu 3.1.1.1.x - Cooling absolute start ........................................................ 28
Menu 3.1.1.1.x - Heating absolute start ........................................................ 28
Generally on temperature regulation .............................................................28
Menu 3.1.8 - Temperature limits.....................................................................28
Menu 3.1.1.1.x - Supply air regulation, absolute ...........................................30
Menu 3.1.1.1.x - Room temperature regulation, absolute .............................31
Menu 3.1.1.1.x - Supply air regulation, relative .............................................32
Menu 3.1.1.1.x - Room temperature regulation, relative ...............................34
Menu 3.1.1 - Operation settings - Temperature regulation.............................. 35
Compensation...................................................................................................... 36
Menu 3.1.2 - Air compensation........................................................................... 36
Menu 3.1.2.1 - CO2 compensation ............................................................... 37
Menu 3.1.2.2 - Humidity compensation of airflow ......................................... 38
Menu 3.1.2.3 - Airflow reduction ................................................................... 38
Menu 3.1.2.4 - Outdoor compensation of airflow .......................................... 39
Menu 3.1.3 - Temperature compensation.......................................................... 40
Outdoor air temperature compensation (menu 3.1.2.1) ................................40
Summertime compensation (menu 3.1.2.2) ..................................................41
Menu 3.1.4 + Menu 8.1 - Filter (monitoring in case of pressure) .................. 41
Menu 3.1.4 + Menu 8.1 - Filter (monitoring with hour counter) ..................... 42
Menu 3.1.5 - Night-time cooling .................................................................... 42
Menu 3.1.6 - Cold recovery............................................................................45
Menu 3.1.7 - Fan limits...................................................................................45
Menu 3.1.8 - Temperature limits for supply air and room...............................45