EPSON Stylus PHOTO 950
Revision A
ADJUSTMENT
Adjustment
152
6. Check the right parallel adjust bushing is normal position, and change to normal
position if the right parallel adjust bushing is in envelope position.
7. Move the carriage unit on the placed thickness gauge by using timing belt, and
check whether the placed thickness gauge moves or not.
NOTE:
If you push the carriage unit directly, printhead surface is possible to be
had a damaging caused by the friction with the thickness gauge.
NOTE:
Following is the relationship between "Right parallel adjust bushing
operation" and "platen gap reaction".
Figure 5-37. Relationship between Bushing Operation & Platen Gap
8. Accede to following steps until you've completed the right side PG adjustment.
Figure 5-38. Right Side PG Adjustment
9. One notch down the Parallel adjust bushing, and then tighten a screw securing
Parallel adjust bushing temporary.
PG Down (Narrower)
PG Up (Wider)
START
Move the CR unit using
timing belt.
Thickness
Gauge moves?
One notch up the Parallel
adjust bushing.
One notch down the Parallel
adjust bushing.
Move the CR unit using
timing belt.
Thickness Gauge
moves?
Advance to Step 9.
Step 8
Yes
Yes
No
No
NOTE:
"down" means PG (Platen Gap) wide.
NOTE:
"up" means
PG (Platen Gap)
narrow.
Summary of Contents for Stylus Photo 950
Page 1: ...EPSONStylusPHOTO950 Color Inkjet Printer SEIJ01 015 SERVICE MANUAL ...
Page 5: ...Revision Status Revision Issued Date Description A April 5 2002 First Release ...
Page 8: ...C H A P T E R 1 PRODUCTDESCRIPTION ...
Page 25: ...C H A P T E R 2 OPERATINGPRINCIPLES ...
Page 53: ...C H A P T E R 3 TROUBLESHOOTING ...
Page 91: ...C H A P T E R 4 DISASSEMBLYANDASSEMBLY ...
Page 132: ...C H A P T E R 5 ADJUSTMENT ...
Page 158: ...C H A P T E R 6 MAINTENANCE ...
Page 174: ...C H A P T E R 7 APPENDIX ...
Page 188: ......
Page 189: ......
Page 190: ......
Page 191: ......