CHAPTER 8 FUNCTION OPTION GENERATOR <winfog>
54
EPSON
S5U1C88000C MANUAL II
WORKBENCH/DEV TOOLS/OLD ASSEMBLER
CHAPTER
8 F
UNCTION
O
PTION
G
ENERATOR
<winfog>
8.1 Outline of winfog
The S1C88 chip allows several hardware specifications such as I/O port functions to be selected as mask
options. This helps you to configure the hardware of your product by changing the S1C88 chip's mask
patterns according to its specifications.
The Function Option Generator <winfog> is the software tool for creating the files necessary to generate
mask patterns. Its graphical user interface (GUI) ensures easy selection mask options. From the files
created by winfog, Seiko Epson produces the mask patterns for the S1C88 chip.
In addition, simultaneously with this file, winfog can create mask option setup files (Motorola S2 format
data) that are required when debugging programs with the ICE (S5U1C88000H5). When using the ICE to
debug a program, you can download this file from the host computer, making it possible to materialize
optional functions on the ICE that are equivalent to those on the actual IC.
8.2 Input/output Files
Figure 8.2.1 shows the input/output files of winfog.
Selection of
mask options
winfog
Function option
HEX file
Function option
document file
Device information
definition file
To ICE
Mask data creation
by mask data checker
s1c88xxx.ini
zzzzzzzz.fsa
zzzzzzzz.fdc
Fig. 8.2.1 Input/output files of winfog
Device information definition file (s1c88xxx.ini)
This file contains option lists for various types of microcomputers and other information. Always be
sure to use the files presented by Seiko Epson. This file is effective for only the type of microcomputer
indicated by the file name. Do not modify the contents of the file or use the file in other types of
microcomputers.
Function option document file (zzzzzzzz.fdc)
This is a text format file in which the contents of selected mask options are stored. You can read this
file into winfog and correct the already selected option settings. This file is packed along with com-
pleted other program/data files into a single file by the mask data checker <winmdc>, which we
would like to have presented to Seiko Epson as the mask data file. From this file, Seiko Epson will
create the mask patterns for the IC.
Function option HEX file (zzzzzzzz.fsa)
This is the Motorola S2 format file necessary to set the selected mask options in the ICE. When you
debug programs with the ICE, download this file into the ICE using an ICE command.
∗
1 The "xxx" in the file name denotes the model name of a microcomputer. For the "zzzzzzzz" part, any
given file name can be specified.
∗
2 For details on how to download mask options into the ICE, refer to the ICE manual.