A
B
30%
103,000 hours
When Constant Brightness is set to On
: Brightness Level
: Standard constant time (Approximate time for which constant
brightness of the light source can be maintained)
A
B
Illustration
85%
7,000 hours
80%
15,000 hours
70%
25,000 hours
60%
35,000 hours
50%
47,000 hours
40%
66,000 hours
30%
95,000 hours
a
This is an approximate guide only and may change depending on
the projector’s usage and surroundings.
The times above are the standard hours when using the projector
continuously without changing the
Brightness Level
or
Constant
Brightness
settings and are not guaranteed.
This is an approximate guide only and may change depending on
the projector’s usage and surroundings. You may need to replace
internal parts sooner than the estimated light source operation time.
When
Constant Brightness
is set to
On
, and the approximate
constant time has been exceeded, you may not be able to set a high
value for
Brightness Level
.
Setting the Amount of Light of the Projected
Image
By automatically setting the luminance according to the brightness of the
displayed image, it lets you enjoy deep and rich images. You can also set
the light source to turn off automatically.
a
Press the [Menu] button while projecting.
b
Select
Light Source Control
from
Image
, and then press the [
]
button.
c
Select
Light Source Control
, and then press the [
] button.
d
Select the light source operation according to the image signal,
and then press the [
] button.
Adjusting Projected Images
77
Summary of Contents for EB-L30000U
Page 1: ...User s Guide ...
Page 16: ...Introduction This chapter explains the names for each part ...
Page 56: ...Basic Usage This chapter explains how to project and adjust images ...
Page 120: ...Security Functions 120 ...
Page 136: ...Configuration Menu This chapter explains how to use the Configuration menu and its functions ...
Page 229: ...Appendix ...