Epson Artisan 700/Epson Stylus Photo PX700W/TX700W
Revision C
DISASSEMBLY/ASSEMBLY
Disassembly/reassembly procedures specific to Artisan 700/PX700W/TX700W
200
Confidential
2.
Disconnect the AID cable from the connector on the SUB Board, and remove
the Card Slot Assy.
Figure 4-239. Removing the Card Slot Assy (2)
4.3.3 Disassembling the Scanner Unit (Artisan 700/
PX700W/TX700W)
4.3.3.1 Document Cover
Parts/Components need to be removed in advance:
Scanner Unit/ADF Unit
Removal procedure
1.
Release the dowels (x2) and ribs (x2) of the Document Cover with the
Document Cover closed, and remove the Document Cover from the Scanner
Upper Housing in the direction of the arrow.
Figure 4-240. Removing the Document Cover
Connect the AID cable properly to the connector on the SUB
Board. (See
Fig. 4-239
.)
Align the grooves (x2) of the Card Slot Assy with the dowels (x2)
of the Base Frame. (See
Fig. 4-238
.)
When attaching the Grounding Plate, install it over the Card
Slot Assy, and tighten them together with the screw. (See
Fig.
4-238
.)
For routing the FFCs, see
4.4 "Routing FFC/cables"
(p202)
.
A D J U S T M E N T
R E Q U I R E D
After removing/replacing the Card Slot Assy, make the specified
adjustments. (See
Chapter 5 "ADJUSTMENT"
.)
AID cable
Card Slot Assy
Connector on the SUB Board
C H E C K
P O I N T
Dowel
Rib
Scanner Upper Housing
Document Cover
Summary of Contents for Artisan 700 Series
Page 7: ...Confidential C H A P T E R 1 PRODUCTDESCRIPTION ...
Page 42: ...Confidential C H A P T E R 2 OPERATINGPRINCIPLES ...
Page 48: ...Confidential C H A P T E R 3 TROUBLESHOOTING ...
Page 189: ...Confidential C H A P T E R 5 ADJUSTMENT ...