Epson Artisan 700/Epson Stylus Photo PX700W/TX700W
Revision C
DISASSEMBLY/ASSEMBLY
Disassembly Procedures
158
Confidential
4.2.4.17 Transmission Holder Assy
Parts/Components need to be removed in advance:
Main Frame/Printhead/CR Scale/Carriage Unit/Ink System
Removal procedure
1.
Push the Switch Lever in the direction of the arrow and disengage the
Transmission Arm from the Transmission Holder Assy. (See
Fig. 4-86
,
Fig.
4-140
.)
2.
Remove the screw (x1) that secures the Transmission Holder Assy. (See
Fig.
4-140
.)
3.
Release the PE Sensor Cable from the Transmission Holder Assy, and remove
the Transmission Holder Assy.
Figure 4-140. Removing the Transmission Holder Assy
C H E C K
P O I N T
The Main Frame becomes unstable once it is removed from the
Base Frame. Be careful not to deform the frame during
performing the following procedures.
Refer to
4.2.4.11 Main Frame (p144)
for the Parts/Components
need to be removed before removing the Main Frame.
Switch Lever
Transmission Arm
C.B.P. 3x8 (6±1Kgfcm)
Transmission Holder Assy
PE Sensor Cable
Make sure that all gears on the Transmission Holder Assy are
properly installed to the hooks and move smoothly.
Figure 4-141. Installing the Transmission Holder Assy (1)
When assembling the Transmission Holder Assy, align the
hooks (x3) of the Transmission Holder Assy with the ribs (x3)
of the Main Frame.
Figure 4-142. Installing the Transmission Holder Assy (2)
For routing the FFCs, see
4.4 "Routing FFC/cables"
(p202)
.
Hook
Bottom side
Rib of the Main Frame
Transmission Holder Assy
Hook