Epson Artisan 700/Epson Stylus Photo PX700W/TX700W
Revision C
DISASSEMBLY/ASSEMBLY
Disassembly Procedures
132
Confidential
4.2.4.4 CSIC Assy
Parts/Components need to be removed in advance:
ADF Unit (Artisan 800/PX800FW/TX800FW only)/Scanner Unit/Upper Left
Housing/Paper Guide Top Assy/Upper Housing
Removal procedure
1.
Disconnect the CSIC FFC from the CSIC connector.
Figure 4-74. Removing the CSIC Assy (1)
2.
Release the hooks (x2) on the rear of the Cartridge Box, and remove the CSIC
Assy upward.
Figure 4-75. Removing the CSIC Assy (2)
C H E C K
P O I N T
In the case of Artisan 700/PX700W/TX700W, removing the Right
Rear Housing
(p192)
and the Right Housing
(p193)
earlier will make
the operation easier.
CSIC connector
CSIC FFC
FFC
Hook
CSIC Assy
Summary of Contents for Artisan 700 Series
Page 7: ...Confidential C H A P T E R 1 PRODUCTDESCRIPTION ...
Page 42: ...Confidential C H A P T E R 2 OPERATINGPRINCIPLES ...
Page 48: ...Confidential C H A P T E R 3 TROUBLESHOOTING ...
Page 189: ...Confidential C H A P T E R 5 ADJUSTMENT ...