1 - 82
Chapter 1 Troubleshooting
Epson AcuLaser C2900N
Revision B
Confidential
9
Checking the HOLDER ASSY RETARD on the Tray 1 for
shape and rotation.
Pull the Tray 1 out from the printer.
Is the HOLDER ASSY RETARD not contaminated and/or
damaged, and rotated smoothly?
Go to step 10.
Replace the
HOLDER ASSY
RETARD. (Refer
to RRP2.2.)
10
Checking the ROLL ASSY FEED for shape and rotation.
Pull the Tray 1 out from the printer.
Is the ROLL ASSY FEED not contaminated and/or
damaged, and rotated smoothly?
Go to step 11.
Replace the ROLL
ASSY FEED.
(Refer to RRP3.5.)
11
Checking the Cassette Feed Solenoid (SOLENOID FEED)
for operation.
Does the Cassette Feed Solenoid (SOLENOID FEED)
operate properly?
Checked by [Digital Output] - [Tray1 Feed Solenoid] in [IOT
Diag] of diagnosis.
During this check, cheat the interlock switch (HARN ASSY
INTERLOCK).
Replace the
CASSETTE ASSY
250. (Refer to
RRP2.1.)
Go to step 21.
12
Checking the paper lead edge staying position.
Does the paper lead edge stay before the ROLL ASSY
REGI and ROLL REGI METAL?
Go to step 13.
The paper lead
edge stay after the
ROLL ASSY REGI
and ROLL REGI
METAL, then go to
step 16.
13
Checking the paper transfer path between the ROLL ASSY
FEED and ROLL ASSY REGI.
Are there any obstacles on the paper transfer path?
Remove the
obstacles or stains
from the paper
transfer path.
Go to step 14.
14
Checking the ACTUATOR REGI IN for shape and operation.
Remove the CHUTE ASSY LOW (PL3.2.27) once to check
the shape and operation.
Are the shape and operation of the ACTUATOR REGI IN
normal?
Go to step 15.
Reseat the
ACTUATOR REGI
IN. (Refer to
RRP3.7.) If broken
or deformed,
replace it.
15
Checking the Regi. Sensor (SENSOR PHOTO) for
operation.
Does the number on the screen increase by one, when the
actuator (ACTUATOR REGI IN) is operated?
Remove the CHUTE ASSY LOW (PL3.2.27) once to check
the operation.
Checked by [Digital Input] - [Regi Sensor] in [IOT Diag] of
diagnosis.
Go to step 16.
Go to step 25.
16
Checking the Regi. Clutch (CLUTCH ASSY DRV) for
operation, and ROLL ASSY REGI and ROLL REGI METAL
for rotation.
Checked by [Digital Output] - [Regi Clutch] in [IOT Diag] of
diagnosis.
Does the Regi. Clutch (CLUTCH ASSY DRV) operate
properly, and the ROLL ASSY REGI and ROLL REGI
METAL rotate?
During this check, cheat the interlock switch (HARN ASSY
INTERLOCK).
Go to step 17.
Go to step 29.
Step
Check
Remedy
Yes
No
Summary of Contents for AcuLaser C2900N
Page 12: ...Confidential CHAPTER 1 Troubleshooting ...
Page 202: ...Confidential CHAPTER 2 Operation of Diagnostic ...
Page 253: ...Confidential CHAPTER 3 Removal and Replacement Procedures ...
Page 497: ...Confidential CHAPTER 4 Plug Jack P J Connector Locations ...
Page 508: ...Confidential CHAPTER 5 Parts List ...
Page 555: ...Confidential CHAPTER 6 Principles of Operation ...
Page 630: ...Confidential CHAPTER 7 Wiring Diagrams and Signal Information ...
Page 660: ...Confidential CHAPTER 8 Product Specifications ...
Page 674: ...8 13 Chapter 8 Product Specifications Epson AcuLaser C2900N Revision B Confidential ...