2 - 14
Chapter 2 Operation of Diagnostic
Epson AcuLaser C2900N
Revision B
Confidential
- Checking the Sensor and Switch
Sensor Name (Diag. Code)
Check Procedure
Manual Feed Sensor
(DI-0)
1)
Power on the printer, and enter the Diag Mode.
2)
Execute DI-0.
3)
Insert a sheet into the Manual Feed to check whether the sensor
functions properly.
4)
Confirm that the number shown on the bottom of the display
increases each time the sheet is inserted.
5)
Press the "STOP" key to stop the test.
Tray1 No Paper Sensor
(DI-1)
1)
Power on the printer, and enter the Diag Mode.
2)
Remove the paper from Tray1.
3)
Execute DI-1.
4)
Check whether the sensor functions properly by removing and
replacing the Tray1.
5)
Confirm that the number in the lower section of the display
increases each time the Tray1 is removed and replaced.
6)
Press the "STOP" key to stop the test.
MiS02003SA
MiS02004SA