Chapter 3 Removal and Replacement Procedures
Revision B
Epson AcuLaser C2900N
3 - 179
Confidential
[Replacement]
1) Attach the GEAR P2 to the shaft of
DRIVE ASSY SUB.
Note: Ensure that the GEAR P2 is
oriented to the direction shown in the
right.
2) Engage the connector (J261) of the
HARN ASSY KSNR REGCL with the Color
mode switching sensor of the DRIVE
ASSY PH, route the HARN ASSY KSNR
REGCL through the hook of the DRIVE
ASSY PH.
Note: When carrying out the work
described next procedure, take care not
to drop the coupling gear to inside.