Chapter 3 Removal and Replacement Procedures
Revision B
Epson AcuLaser C2900N
3 - 73
Confidential
7) Close the ACTUATOR REGI OUT by
inserting the boss of the ACTUATOR REGI
OUT into the SPRING REGI OUT.
8) Shift the ACTUATOR REGI OUT to left,
fix the CHUTE UP using the hook.
9) Attach the ACTUATOR REGI ROLL M
by mating the hole of the ACTUATOR
REGI ROLL M with the tab of the
ACTUATOR REGI OUT. Fix it using the
hook of the ACTUATOR REGI OUT.
Note: Check the ACTUATOR REGI OUT and the ACTUATOR REGI IN movement, after the
procedure 9 is completed.