Chapter 3 Removal and Replacement Procedures
Revision B
Epson AcuLaser C2900N
3 - 79
Confidential
19) Release the ACTUATOR REGI OUT
from the hook on the CHUTE UP
(PL3.2.26), open the ACTUATOR REGI
OUT.
20) Release the three hooks that fix the
SENSOR PHOTO: REGI (PL3.2.13) to the
FEEDER ASSY MG SFP (PL3.1.98), and
remove the SENSOR PHOTO: REGI.
Note: When carrying out the work this
procedure, it is easier to push the
ACTUATOR.
21) Disengage the connector (P/J232) of
the SENSOR PHOTO: REGI.
Summary of Contents for AcuLaser C2900N
Page 12: ...Confidential CHAPTER 1 Troubleshooting ...
Page 202: ...Confidential CHAPTER 2 Operation of Diagnostic ...
Page 253: ...Confidential CHAPTER 3 Removal and Replacement Procedures ...
Page 497: ...Confidential CHAPTER 4 Plug Jack P J Connector Locations ...
Page 508: ...Confidential CHAPTER 5 Parts List ...
Page 555: ...Confidential CHAPTER 6 Principles of Operation ...
Page 630: ...Confidential CHAPTER 7 Wiring Diagrams and Signal Information ...
Page 660: ...Confidential CHAPTER 8 Product Specifications ...
Page 674: ...8 13 Chapter 8 Product Specifications Epson AcuLaser C2900N Revision B Confidential ...