Chapter 3 Removal and Replacement Procedures
Revision B
Epson AcuLaser C2900N
3 - 56
Confidential
[Replacement]
1) Mate the holes of the SOLENOID FEED
MSI with the two bosses of the printer,
secure the SOLENOID FEED MSI with the
one screw (silver, tap, 8mm).
2) Engage the connecter (P/J231) of the
SOLENOID FEED MSI, secure the relay
connector with the rib of the printer.
3) Route the harness of the SOLENOID
FEED MSI through the hooks of the printer.
Note: When carrying out the work described next procedure, it is easier to put the D-cut surface
of the SHAFT ASSY FEED on the front.