2 - 15
Chapter 2 Operation of Diagnostic
Epson AcuLaser C2900N
Revision B
Confidential
Regi Sensor
(DI-2)
NOTE: When performing operation for five minutes or longer with the
front cover open, remove the drum cartridge, and cover the drum to
avoid exposure to light.
1)
Power on the printer, and enter the Diag Mode.
2)
Open the Front Cover.
3)
Execute DI-2.
4)
Manually operate the actuator to check whether the sensor
functions properly.
5)
Check that the number in the bottom line of the display
increases by one every time the actuator is operated.
6)
Press the "STOP" key to stop the test.
7)
Close the Front Cover.
Exit Sensor
(DI-3)
NOTE: Because the fuser unit is very hot, be careful not to burn
yourself.
1)
Power on the printer, and enter the Diag Mode.
2)
Open the Front Cover.
3)
Execute DI-3.
4)
Manually operate the actuator to check whether the sensor
functions properly.
5)
Check that the number in the bottom line of the display
increases by one every time the actuator is operated.
6)
Press the "STOP" key to stop the test.
7)
Close the Front Cover.
Sensor Name (Diag. Code)
Check Procedure
Actuator
MiS02005SA
MiS02006GA
Summary of Contents for AcuLaser C2900N
Page 12: ...Confidential CHAPTER 1 Troubleshooting ...
Page 202: ...Confidential CHAPTER 2 Operation of Diagnostic ...
Page 253: ...Confidential CHAPTER 3 Removal and Replacement Procedures ...
Page 497: ...Confidential CHAPTER 4 Plug Jack P J Connector Locations ...
Page 508: ...Confidential CHAPTER 5 Parts List ...
Page 555: ...Confidential CHAPTER 6 Principles of Operation ...
Page 630: ...Confidential CHAPTER 7 Wiring Diagrams and Signal Information ...
Page 660: ...Confidential CHAPTER 8 Product Specifications ...
Page 674: ...8 13 Chapter 8 Product Specifications Epson AcuLaser C2900N Revision B Confidential ...