1 - 155
Chapter 1 Troubleshooting
Epson AcuLaser C2900N
Revision B
Confidential
FIP-1.P10 Light-Induced Fatigue
Possible causative parts
- DRUM CARTRIDGE (PL4.1.21)
Before commencing troubleshooting, check the paper transfer path. Make sure there is no foreign
materials on the transfer path, such as staples, paper clips, scraps of paper and so on.
Step
Check
Remedy
Yes
No
1
Checking after "Drum Refresh Mode".
Execute the "Drum Refresh Mode".
- To execute the "Drum Refresh Mode", click [Drum Refresh
Mode] in [Refresh Mode] on the diagnosis tab of Tool Box.
Is the image printed correctly?
End of work.
Go to step 2.
2
Checking after replacing the DRUM CARTRIDGE.
Replace the DRUM CARTRIDGE. (Refer to RRP4.6.)
Does the error still occur when printing?
Replace the
Printer.
End of work.
Summary of Contents for AcuLaser C2900N
Page 12: ...Confidential CHAPTER 1 Troubleshooting ...
Page 202: ...Confidential CHAPTER 2 Operation of Diagnostic ...
Page 253: ...Confidential CHAPTER 3 Removal and Replacement Procedures ...
Page 497: ...Confidential CHAPTER 4 Plug Jack P J Connector Locations ...
Page 508: ...Confidential CHAPTER 5 Parts List ...
Page 555: ...Confidential CHAPTER 6 Principles of Operation ...
Page 630: ...Confidential CHAPTER 7 Wiring Diagrams and Signal Information ...
Page 660: ...Confidential CHAPTER 8 Product Specifications ...
Page 674: ...8 13 Chapter 8 Product Specifications Epson AcuLaser C2900N Revision B Confidential ...