FIP-1.53 091-972: IOT PHD Detached
Step
Check
Remedy
Yes
No
Possible causative parts:
DRUM CARTRIDGE (PL4.1.21)
PWBA MCU (PL8.2.13)
HARN ASSY PHD XPRO (PL9.1.11)
1
Checking after resetting the DRUM CARTRIDGE.
Reseat the DRUM CARTRIDGE.
Does the error still occur when the power is turned OFF and
ON?
Go to step 2.
End of work.
2
Checking the connectors for connection.
Check the connectors between the PWBA MCU and DRUM
CARTRIDGE.
Are P/J42 and P/J422 connected correctly?
Go to step 4.
Reconnect the
connector(s) P/
J42 and/or P/J422
surly, then go to
step 3.
3
Does the error still occur when the power is turned OFF and
ON?
Go to step 4.
End of work.
4
Checking the HARN ASSY PHD XPRO for continuity.
Disconnect P422 from the DRUM CARTRIDGE.
Disconnect J42 from the PWBA MCU.
Is each cable of P422 <=> J42 continuous?
Go to step 5.
Replace the
HARN ASSY PHD
XPRO.
5
Checking after replacing the DRUM CARTRIDGE.
Replace the DRUM CARTRIDGE. (Refer to RRP4.6.)
CAUTION: Be sure to pull eight sealing tapes out from a
new DRUM CARTRIDGE before installation.
Does the error still occur when the power is turned OFF and
ON?
Replace the
PWBA MCU.
(Refer to RRP8.9.)
End of work.
Summary of Contents for AcuLaser C2900N
Page 12: ...Confidential CHAPTER 1 Troubleshooting ...
Page 202: ...Confidential CHAPTER 2 Operation of Diagnostic ...
Page 253: ...Confidential CHAPTER 3 Removal and Replacement Procedures ...
Page 497: ...Confidential CHAPTER 4 Plug Jack P J Connector Locations ...
Page 508: ...Confidential CHAPTER 5 Parts List ...
Page 555: ...Confidential CHAPTER 6 Principles of Operation ...
Page 630: ...Confidential CHAPTER 7 Wiring Diagrams and Signal Information ...
Page 660: ...Confidential CHAPTER 8 Product Specifications ...
Page 674: ...8 13 Chapter 8 Product Specifications Epson AcuLaser C2900N Revision B Confidential ...