Chapter 3 Removal and Replacement Procedures
Revision B
Epson AcuLaser C2900N
3 - 71
Confidential
[Replacement]
1) After the inserting the left shaft of the
ROLL ASSY REGI into the hole of the
FEEDER ASSY MG SFP, insert the right
shaft of the ROLL ASSY REGI into the
hole. Attach the ROLL ASSY REGI
together with the ACTUATOR REGI OUT
and the ACTUATOR REGI ROLL M.
Note: When carrying out the work this
procedure, move the ACTUATOR REGI
OUT to right until it stops.
2) Attach the BEARING R to the ROLL
ASSY REGI.
Note: When carrying out the work this
procedure, it is easier to push the ROLL
REGI METAL (PL3.2.10) to frontward.
3) Secure the BEARING R to the ROLL
ASSY REGI with the E-ring by using the
pliers.