Chapter 6
Troubleshooting & Repairs
6.1. Introduction
This chapter details the steps to troubleshoot and repair the
FLEX
.
6.2. FLEX Error Messages
Table 6-1 lists all of the error messages, their causes, and troubleshooting steps for each.
TABLE 6-1.
FLEX Error Messages
Error# Error Message
Cause
Troubleshooting
9000
No Response to Hardware-Init
RVM not operational
Contact Envipco Support
The
RVM
initialization
timed out after 30 seconds.
Check harnesses and connections. If
that fails, replace the
RVM
controller.
9001
Bus-Electronic is not responding
RVM not operational
Contact Envipco Support
No micro controllers
were found on the
system bus.
Check harnesses and connections. If
that fails, replace the
RVM
controller.
9002
Bus-Electronic differs from
Configuration
RVM not operational
Contact Envipco Support
One or more clients are
missing from the system
bus.
Check harnesses and connections. If
that fails, replace the
RVM
controller.
9005
Hardware Init
-> Cabinet not closed
RVM not operational
Close all Doors!
The
RVM
will not operate
because the safety interlock
is activated. A door is open
or the magnetic door sensors
are mal- functioning.
Make sure that all doors are closed. If the
doors are closed, check the Diagnostic Pro-
gram (Main / Safety Loop) to see what is
causing this message.
9006
No Hardware Layer
RVM not operational
Contact Envipco Support
The Hardware Process is
not running on the
PC
board.
Check harnesses and connections. If
that fails, replace the
RVM
controller.
9007
Service Mode
is active
>> Service Mode <<
not permitted at Systemstart
Contact Envipco Support
The
RVM
will not operate
while it is in Service
Mode.
Exit Service Mode, and remove your
override key.
9008
Cabinet Door open
Safety breach!
RVM not operational
Close all Doors!
The
RVM
will not operate if
one of the doors is open.
This is a catch-all error
message.
Make sure that all doors are closed. If the
doors are closed, check the Diagnostic Pro-
gram (Main / Safety Loop) to see what is
causing this message.
6-1
Summary of Contents for FLEX Dual
Page 1: ...FLEX Series ServiceManual March 16 2016...
Page 2: ......
Page 14: ...1 6 Chapter 1 Introduction Safety FLEX HDS LASER DANGER LABEL...
Page 21: ...1 13 Safety labels FLEX HDS ONLY RIGHT PANEL KEEP HANDS AWAY WARNING LABEL 1 13...
Page 28: ...Chapter 2 Specifications 2 6 Notes...
Page 50: ...RVM Controller Box 3 19 FIGURE 3 18 MC5 BoardLayout FIGURE 3 19 MD5 BoardLayout 3 22...
Page 57: ...3 26 Chapter 3 Hardware Components Notes...
Page 58: ......
Page 84: ...4 26 Chapter 4 RVM Software MC1 Board FLEX DFF FLEX DFF GDS AC MOTOR CONTROL BOX...
Page 85: ...4 27 Software Theory of Operation Notes...
Page 86: ...4 28 Chapter 4 RVM Software Notes...
Page 94: ...5 8 Chapter 5 Maintenance Notes...
Page 106: ...Chapter 6 Troubleshooting Repairs Notes 6 12...
Page 107: ...Repairs Notes 6 13...
Page 108: ...Chapter 6 Troubleshooting Repairs Notes 6 14...
Page 109: ...Repairs Notes 6 15...
Page 110: ...Chapter 6 Troubleshooting Repairs Notes 6 16...
Page 111: ...Repairs Notes 6 17...
Page 112: ...Chapter 6 Troubleshooting Repairs Notes 6 18...
Page 113: ...Repairs Notes 6 19...
Page 114: ...Chapter 6 Troubleshooting Repairs Notes 6 20...