clear spantree lpwindow
SecureStack C2 Configuration Guide
7-47
Defaults
None.
Mode
Switch
command,
read
‐
only.
Example
This
example
shows
how
to
display
the
current
Loop
Protect
window
value:
C2(rw)->show spantree lpwindow
The Loop Protect event window is set to 120 seconds
clear spantree lpwindow
Use
this
command
to
reset
the
Loop
Protect
event
window
to
the
default
value
of
180
seconds.
Syntax
clear spantree lpwindow
Parameters
None.
Defaults
None.
Mode
Switch
command,
read
‐
write.
Example
This
example
shows
how
to
reset
the
Loop
Protect
event
window
to
the
default
of
180
seconds:
C2(rw)->clear spantree lpwindow
set spantree lptrapenable
Use
this
command
to
enable
or
disable
Loop
Protect
event
notification.
Syntax
set spantree lptrapenable
{
enable
|
disable
}
Parameters
Defaults
None.
enable
|
disable
Enables
or
disables
the
sending
of
Loop
Protect
traps.
Default
is
disabled.
Summary of Contents for SecureStack C2
Page 1: ...SecureStack C2 Stackable Switches Configuration Guide Firmware Version 5 1 xx P N 9033991 16 ...
Page 2: ......
Page 28: ...xxvi ...
Page 106: ...set ssl 3 52 Basic Configuration ...
Page 226: ...Creating a Basic SNMP Trap Configuration 6 38 SNMP Configuration ...
Page 278: ...show spantree nonforwardingreason 7 52 Spanning Tree Configuration ...
Page 302: ...set garp timer 8 24 802 1Q VLAN Configuration ...
Page 448: ...show dhcp pool configuration 14 30 DHCP Server Configuration ...
Page 454: ...no license advanced 15 6 Preparing for Router Mode ...