INTELLIGEN MV DISPENSE SYSTEM
ENTEGRIS, INC.
INSTALLATION AND USE MANUAL P/N P92500 REV. A
13
5. Slide in a new filter.
WARNING! PINCH HAZARD! Keep
fingers clear of jaw mechanism
to prevent personal injury.
6. Keep your fingers
CLEAR
of the jaws, then
lower the lever until the tab clicks into place
on the filter.
Step 6: Connect Fluid Lines
Minimize tubing lengths whenever possible and
maximize fluid tubing size wherever practical to
further reduce pressure drop through the tubing.
Use the shortest tube length practical, while
providing adequate service loops.
As a general rule, minimize the distance between
the source liquid and the system and between the
system and the point-of-dispense.
CAUTION! DRIP HAZARD! Do not over-tighten
fittings. Excessive force will damage the
internal seals. Tighten the fittings by hand;
then use a small adjustable wrench to tighten
for the final
1
⁄
4
turn.
1. Insert Pillar sleeve and tube assembly into the
fluid fitting adapter.
2. Hand tighten Pillar nut.
3. Use a 13 mm wrench to hold the fluid fitting
adapter from turning when tightening the
Pillar nut, sleeve and tube assembly.
This is only to hold, Not to turn it.
4. While holding the fluid fitting adapter with
the 13 mm wrench tighten the Pillar nut
using a 16 mm wrench to the specified Pillar
recommended specifications.
CAUTION! Tightening the union nut:
Refer to Super Type Pillar Fitting
Instruction Manual No. 048L-1.
Refer to the standard Super 300 Type Pillar or
Flowell manufacturer’s installation instructions
for the making of
other fitting connections.
!
!
!