Alarm messages
If a fault occurs with a sensor, for instance, an alarm is triggered. A message
appears on the display with information about the fault. In the event of an
alarm, the LEDs on the display and room sensor also l ash.
You reset the alarm by pressing the “Reset alarm” button on the display.
If several alarms are triggered, they are displayed one after the other. An
outstanding fault cannot be reset without being rectii ed i rst. Some alarms
are reset automatically if the fault disappears.
Alarm Text
Description
Wrong phase order compressor
The product’s compressor motor must rotate in the right direction. The
product checks that the phases are connected correctly; otherwise, an
alarm is triggered. In this case, two of the phases to the product need to be
changed. The power supply to the system must be shut off when rectifying
this fault. This fault generally only occurs during installation.
Alarm sensor
An alarm is displayed if a fault occurs with a sensor that is not connected or
has short-circuited. If this sensor is signii cant to the system’s operation, the
compressor stops. In this case, the alarm is reset manually after the fault
has been rectii ed.
B1
Primary l ow sensor 1
B12
Room sensor 2
B2
Primary l ow sensor 2
B13
Room sensor 3*
B3
Primary l ow sensor 3*
B14
Room sensor 4*
B4
Primary l ow sensor 4*
B15
Outdoor sensor
B5
Sensor, hot water tank
B30
Sensor in to solar panels*
B6
Sensor buffer tank
B31
Sensor out from solar panels*
B9
Sensor external boiler
B41
Sensor external DHW tank
B10
Sensor external boiler out
B50
Sensor pool
B11
Room sensor 1
and for heat pumps A1–A10:
Sensor brine out
Sensor brine in
Sensor HPin
Sensor HPout
Sensor discharge
Sensor suction gas
Sensor high pressure
Sensor low pressure
Motor protect compressor
High/low current has been detected to the compressor. Press reset and
check whether the alarm recurs. If the fault recurs, contact your installer.
High pressure switch
The refrigerant’s high pressure switch has been triggered. Press reset and
check whether the alarm recurs. If the fault recurs, contact your installer.
*Applies to the CTC EcoLogic PRO only.
Summary of Contents for CTC EcoLogic Family series
Page 2: ......
Page 3: ...162 105 48 3 2016 04 08 Installation and Maintenance Manual CTC EcoLogic Pro Family...
Page 67: ...67 CTC EcoLogic Pro Family For the property owner...
Page 120: ...120 CTC EcoLogic Pro Family For the installer 11 Wiring diagram...
Page 121: ...121 CTC EcoLogic Pro Family For the installer...
Page 127: ......